Key result
Measuring BP on exam tables instead of chairs misclassifies hypertension in ~16% of patients.
Why the study?
The study was conducted to evaluate two commonly overlooked sources of error in office blood pressure measurement: improper patient positioning and the frequency of terminal digit bias using manual versus automated devices.
Does proper patient positioning in a chair compared to an examination table improve the accuracy of blood pressure measurement and prevent misclassification of hypertension?
Observational (n=294)
No
Does proper patient positioning in a chair compared to an examination table improve the accuracy of blood pressure measurement and prevent misclassification of hypertension?
Measuring blood pressure while patients are seated on an examination table rather than in a chair significantly elevates readings and leads to substantial misclassification of hypertension.
Answers are grounded in this paper and cite their sources.
Office BP protocols must mandate chair positioning and automated devices; confirms positioning and observer bias as modifiable sources of diagnostic error.
PURPOSES: To evaluate 2 commonly overlooked sources of error in measuring blood pressure (BP) in the office, improper patient positioning and frequency of terminal digit bias (TDB) using manual and automated (BP) devices. METHODS: BPs recorded by 3 nurses using manual and automated devices were analyzed for TDB. In the next part of the study, 294 patients were recruited and tested with each patient's BP measured twice in the table position and compared with BP measured in the chair position. To eliminate concern for position sequence, a randomized controlled trial was initially conducted. RESULTS: Significant TDB for the digit zero was identified in BPs measured by all nurses using a manual device. No such bias was identified for any nurse when measuring BP with an automated device. For the positional study, the randomized controlled study showed no significant sequencing effect therefore the sequence of table then chair BP measurements was adopted. Significant BP lowering was observed in 128 patients (42.7%) in the chair compared with the table position. Misclassification of prehypertension and hypertension would have occurred in 15.3% and 16% of patients, respectively, when BP was recorded in the table instead of the chair position. CONCLUSIONS: Significant TDB was identified for all nurses when using a manual but not an automated device. Patient positioning on the examination table resulted in elevations of systolic and diastolic BPs.
No takes yet. Share an insight, caveat, or question.
Morcos et al. (2019) conducted an observational in Hypertension (n=294). Chair positioning during blood pressure measurement vs. Examination table positioning was evaluated on Significant blood pressure lowering in chair compared with table position. Measuring blood pressure on an examination table instead of a chair caused significant BP elevations, misclassifying hypertension in 16.3% of patients, while manual devices exhibited significant terminal digit bias.
Synapse has enriched 10 related papers. Consider them for comparative context: