Key result
The proposed automatic segmentation method achieved a Dice score of 0.87 and a Hausdorff distance of 7.26 mm for right ventricle endocardium segmentation, taking about 3 seconds per volume.
The proposed automatic saliency-based segmentation method provides fast and accurate right ventricle volume estimation from cardiac MRI, comparable to manual expert delineation.
Answers are grounded in this paper and cite their sources.
Automated RV segmentation from short-axis CMR may aid volumetric assessment; leaves open prospective validation before clinical adoption.
PURPOSE: Accurate measurement of the right ventricle (RV) volume is important for the assessment of the ventricular function and a biomarker of the progression of any cardiovascular disease. However, the high RV variability makes difficult a proper delineation of the myocardium wall. This paper introduces a new automatic method for segmenting the RV volume from short axis cardiac magnetic resonance (MR) images by a salient analysis of temporal and spatial observations. METHODS: The RV volume estimation starts by localizing the heart as the region with the most coherent motion during the cardiac cycle. Afterward, the ventricular chambers are identified at the basal level using the isodata algorithm, the right ventricle extracted, and its centroid computed. A series of radial intensity profiles, traced from this centroid, is used to search a salient intensity pattern that models the inner-outer myocardium boundary. This process is iteratively applied toward the apex, using the segmentation of the previous slice as a regularizer. The consecutive 2D segmentations are added together to obtain the final RV endocardium volume that serves to estimate also the epicardium. RESULTS: Experiments performed with a public dataset, provided by the RV segmentation challenge in cardiac MRI, demonstrated that this method is highly competitive with respect to the state of the art, obtaining a Dice score of 0.87, and a Hausdorff distance of 7.26 mm while a whole volume was segmented in about 3 s. CONCLUSIONS: The proposed method provides an useful delineation of the RV shape using only the spatial and temporal information of the cine MR images. This methodology may be used by the expert to achieve cardiac indicators of the right ventricle function.
No takes yet. Share an insight, caveat, or question.
Atehortúa et al. (2016) studied Various cardiac pathologies (n=48). Automatic segmentation using saliency analysis vs. Manual delineation was evaluated on Dice score (DSC) and Hausdorff distance (HD) for right ventricle endocardium segmentation. The proposed automatic segmentation method achieved a Dice score of 0.87 and a Hausdorff distance of 7.26 mm for right ventricle endocardium segmentation, taking about 3 seconds per volume.
Synapse has enriched 10 related papers. Consider them for comparative context: