Answers are grounded in this paper and cite their sources.
The long-term performance of tissue-engineered scaffolds, particularly small-diameter vascular grafts, is shaped by remodeling events at the tissue-graft interface, yet these processes remain difficult to resolve longitudinally and at microstructural resolution in conventional implantation models. Here we develop an organotypic artery-graft model that preserves cylindrical vessel geometry and enables non-destructive label-free multiphoton monitoring of interface remodeling. Using second harmonic generation and two-photon excited fluorescence, we capture evolving fibrillar collagen architecture and cellularization over time, demonstrate compatibility with multiple biomaterial classes, and show integration with rat and mouse explants, live-cell dyes, and fluorescent reporter tissues. The platform resolved distinct remodeling responses to transforming growth factor-β isoforms (TGF-β1, -β2, and -β3), with differential shifts in collagen-fiber distributions, accompanied by changes in matrix-remodeling and contractile gene expression. Across two graft designs, culture-derived remodeling phenotypes, collagen fiber distributions, and initial trajectories agreed with those observed in long-term 6-month interpositional explants. Together, these results establish an accessible intermediate platform for interrogating artery-graft remodeling, tracking these trajectories, and prioritizing graft designs through interface-resolved outcomes before and alongside animal implantation studies.
No takes yet. Share an insight, caveat, or question.
Maestas et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: