Key result
Tc-99m MIBI radionuclide angiocardiography LVEF shows a ~0.83 correlation with contrast X-ray cineangiography.
Why the study?
Does technetium-99m-methoxy isobutyl isonitrile multiple-gated radionuclide angiocardiography accurately measure left ventricular ejection fraction compared to established angiocardiography techniques in patients symptomatic of cardiac disease?
Population
23 patients symptomatic of cardiac disease
Comparison
Technetium-99m-methoxy isobutyl isonitrile… vs Contrast X-ray single-plane cineangiography and…
Design
Cross-sectional
Authors
Loading...
May support MIBI radionuclide angiography for LVEF assessment; leaves open prospective validation in larger cohorts before clinical adoption.
Observational (n=23)
Does technetium-99m-methoxy isobutyl isonitrile multiple-gated radionuclide angiocardiography accurately measure left ventricular ejection fraction compared to established angiocardiography techniques in patients symptomatic of cardiac disease?
Effect estimate: r=0.83
p-value: p=<10(-6)
Technetium-99m-methoxy isobutyl isonitrile multiple-gated radionuclide angiocardiography provides a reliable method for determining left ventricular ejection fraction that correlates well with established imaging techniques.
Davis et al. (1993) conducted an observational in Cardiac disease (n=23). Technetium-99m-methoxy isobutyl isonitrile multiple-gated radionuclide angiocardiography vs. Contrast X-ray single-plane cineangiography was evaluated on Correlation of left ventricular ejection fraction (r=0.83, p=<10(-6)). Left ventricular ejection fraction determined by technetium-99m-methoxy isobutyl isonitrile radionuclide angiocardiography correlated well with contrast X-ray cineangiography (r=0.83, p<10^-6).