Key result
Lateral LV lead position in CRT linked to ~16% lower mortality versus posterior placement.
Why the study?
Selection of a coronary sinus side branch during CRT implantation has been empirical because data on the association between left ventricular lead position and long-term clinical outcomes are limited.
Does a lateral left ventricular lead position reduce long-term all-cause mortality and improve echocardiographic response compared to anterior or posterior positions in heart failure patients undergoing cardiac resynchronization therapy?
Cohort (n=2,087)
No
Does a lateral left ventricular lead position reduce long-term all-cause mortality and improve echocardiographic response compared to anterior or posterior positions in heart failure patients undergoing cardiac resynchronization therapy?
In a large real-world CRT cohort, a true lateral LV lead position provided superior long-term survival compared to both anterior and posterior positions, particularly when achieving an interlead electrical delay >110 ms for optimal reverse remodelling.
Answers are grounded in this paper and cite their sources.
Lateral lead placement may reduce CRT mortality; extends observational data but leaves open randomized confirmation before practice change.
AIMS: Preferring side branch of coronary sinus during cardiac resynchronization therapy (CRT) implantation has been empirical due to the limited data on the association of left ventricular (LV) lead position and long-term clinical outcome. We evaluated the long-term all-cause mortality by LV lead non-apical positions and further characterized them by interlead electrical delay (IED). METHODS AND RESULTS: In our retrospective database, 2087 patients who underwent CRT implantation were registered between 2000 and 2018. Those with non-apical LV lead locations were classified into anterior (n = 108), posterior (n = 643), and lateral (n = 1336) groups. All-cause mortality was assessed by Kaplan-Meier and Cox analyses. Echocardiographic response was measured 6 months after CRT implantation. During the median follow-up time of 3.7 years, 1150 (55.1%) patients died-710 (53.1%) with lateral, 78 (72.2%) with anterior, and 362 (56.3%) with posterior positions. When we investigated the risk of all-cause mortality, there was a significantly lower rate of death in patients with lateral LV lead location when compared with those with an anterior (P < 0.01) or posterior (P < 0.01) position. Multivariate analysis after adjustment for relevant clinical covariates such as age, sex, ischaemic aetiology, left bundle branch block morphology, atrial fibrillation, and device type revealed consistent results that lateral position is associated with a significant risk reduction of all-cause mortality when compared with anterior [hazard ratio 0.69; 95% confidence interval (CI) 0.55-0.87; P < 0.01] or posterior (hazard ratio 0.84; 95% CI 0.74-0.96; P < 0.01) position. When echocardiographic response was evaluated within the lateral group, patients with an IED longer than 110 ms (area under the receiver operating characteristic curve, 0.63; 95% CI 0.53-0.73; P = 0.012) showed 2.1 times higher odds of improvement in echocardiographic response 6 months after the implantation. CONCLUSIONS: In this study, we proved in a real-world patient population that after CRT implantation, lateral LV lead location was associated with long-term mortality benefit and is superior to both anterior and posterior positions. Moreover, patients with this position showed the greatest echocardiographic response over 110 ms IED.
No takes yet. Share an insight, caveat, or question.
Behon et al. (2020) conducted a cohort in Symptomatic chronic systolic heart failure undergoing cardiac resynchronization therapy (n=2,087). Lateral left ventricular lead position during CRT implantation vs. Posterior (n=643) or anterior (n=108) left ventricular lead position was evaluated on All-cause mortality (or composite of all-cause mortality, heart transplantation, or LVAD implantation) (HR 0.84, 95% CI 0.74-0.96, p=<0.01). Lateral LV lead position during CRT reduced long-term all-cause mortality compared to posterior and anterior positions.