Key result
Heart rate deflection methods show large errors compared to gas analysis for assessing anaerobic threshold.
Why the study?
Do heart rate deflection methods accurately predict the anaerobic threshold compared to gas analysis in endurance athletes?
Observational (n=115)
Do heart rate deflection methods accurately predict the anaerobic threshold compared to gas analysis in endurance athletes?
Heart rate deflection methods have large total errors when predicting the anaerobic threshold, limiting their practical value for endurance athletes.
Answers are grounded in this paper and cite their sources.
Clinicians should avoid heart rate deflection methods for anaerobic threshold; leaves open validation of accurate noninvasive alternatives in athletes.
There is perhaps no greater controversy in exercise physiology than the validity, or lack thereof, of the heart rate breakpoint theory in general, and the Conconi test in particular, in assessing the anaerobic threshold. Three heart rate breakpoint methods have been proposed as methods of detecting the anaerobic threshold have appeared in the literature: (1) a breakpoint in linearity of the heart rate–work rate relationship (heart rate breakpoint); (2) a log function curve of the heart rate–work rate relationship (log function); and (3) a combination of linear regression and logarithmic function of the heart rate–work rate relationship (log‐linear). The main aim of this study was to assess the validity of these methods compared with that of gas analysis assessment of the anaerobic threshold. This was a descriptive study of 115 endurance athletes undergoing simultaneous gas analysis and heart rate determination during incremental exercise to exhaustion. The participants were 115 competitive cyclists and/or triathletes (71 males: mean age 38.5 years, s=6.2; 44 females: mean age 37.8 years, s=5.1). Incremental exercise testing to exhaustion was performed on an electrically braked cycle ergometer, commencing at 25 W and increasing by 25 W · min−1 to volitional fatigue. Heart rate was recorded each minute and at exhaustion. Gas analysis was performed using breath‐by‐breath analysis with 10‐s averaging. The anaerobic threshold based on ventilatory parameters was used as the criterion test. Compared with the criterion threshold, no significant differences were observed for the heart rate breakpoint (t=1.12, P=0.268) or log function (t=0.0, P=0.998) methods. However, the log‐linear method (t=2.25, P=0.026) significantly overestimated the anaerobic threshold. Although two of the three heart rate methods were validated in this study, the relatively large total errors for these methods (13.7 beats · min−1 for heart rate breakpoint, 12.5 beats · min−1 for log function, and 14.3 beats · min−1 for log‐linear) indicate that they would have little practical value.
No takes yet. Share an insight, caveat, or question.
Carey et al. (2008) conducted an observational in Anaerobic threshold assessment (n=115). Heart rate deflection methods (heart rate breakpoint, log function, log-linear) vs. Gas analysis assessment was evaluated on Anaerobic threshold (p=0.268 for HR breakpoint, 0.998 for log function, 0.026 for log-linear). Heart rate deflection methods showed large total errors compared to gas analysis for assessing the anaerobic threshold, indicating little practical value.
Synapse has enriched 10 related papers. Consider them for comparative context: