Key result
IVC filter insertion shows low complication rates, with active bleeding prompting ~62% of placements.
Observational (n=77)
No
In a single-center 5-year experience, IVC filter insertion was primarily indicated for active bleeding and associated with a low rate of procedural complications.
Answers are grounded in this paper and cite their sources.
May support IVC filter use for active bleeding given low complications; single-center data leaves open need for confirmatory trials.
BACKGROUND AND OBJECTIVES: Interruption of the Inferior Vena Cava (IVC) is recommended in certain cases to prevent Pulmonary Embolism (PE). Reported data on the efficacy and rate of complications vary considerably. PATIENTS AND METHODS: We conducted a retrospective analysis of patients who had a temporary or permanent IVC filter inserted at our institution during the past 5 years. RESULTS: Seventy-seven of 225 patients (34%) with Venous Thrombosis (VT) had an IVC filter inserted. Deep vein thrombosis and PE were the most common causes for anticoagulation. Bleeding was the reason for IVC filter insertion in 48 (62%). The only complication found was the breaking of a temporary filter during removal related to the procedure. However, 3 patients (out of 10) had a recurrence of VT after prolonged discontinuation of anticoagulation. CONCLUSIONS: Our criteria for indication of IVC filter insertion are in line with current standard of care. The immediate and delayed complications caused by IVC filter insertion was low. Active bleeding was the most common indication for filter insertion, whereas inherited thrombophilia was relatively common.
No takes yet. Share an insight, caveat, or question.
Saour et al. (2009) conducted an observational in Venous Thrombosis (n=77). Inferior Vena Cava (IVC) filter was evaluated. Inferior vena cava filter insertion had a low complication rate, with active bleeding being the primary indication for insertion in 62% of patients.
Synapse has enriched 10 related papers. Consider them for comparative context: