Answers are grounded in this paper and cite their sources.
PURPOSE: To report percutaneous closure of aortocaval fistulas with the Amplatzer Duct Occluder. CASE REPORTS: An aortocaval fistula was diagnosed after surgical repair of an abdominal aortic aneurysm in a 73-year-old man. A 3-year-old girl was treated for a congenital aortocaval fistula in another case. An 8 x 6-mm Amplatzer Duct Occluder was introduced via a 6-F introducer in each case, successfully occluding the fistulous track. Both patients are well and without any echocardiographic evidence of a shunt at 6 months. CONCLUSIONS: In selected patients, transcatheter closure of aortocaval fistula with the Amplatzer Duct Occluder could be an alternative to open surgery. Further evaluation is necessary.
No takes yet. Share an insight, caveat, or question.
Godart et al. (2005) studied this question.