Key result
Medtronic Hall Easy-Fit valves yield elevated HITS in ~25% of patients, correlating with larger sizes.
Why the study?
Does valve size impact the incidence of high-intensity transient signals and hemolysis after aortic valve replacement with the Medtronic Hall Easy-Fit prosthesis?
Cohort (n=150)
Does valve size impact the incidence of high-intensity transient signals and hemolysis after aortic valve replacement with the Medtronic Hall Easy-Fit prosthesis?
Larger sizes of the Medtronic Hall Easy-Fit aortic valve prosthesis are associated with increased high-intensity transient signals and hemolysis, challenging the routine practice of implanting the largest possible valve.
Answers are grounded in this paper and cite their sources.
Larger Medtronic Hall Easy-Fit valves were associated with more HITS and hemolysis; hypothesis-generating for size selection and should not yet change practice.
BACKGROUND AND AIM OF THE STUDY: Previous studies have shown a correlation between type, orientation and valve size of mechanical heart valve prostheses and the incidence of high-intensity transient signals (HITS). The study aim was to investigate the presence of HITS and hemolysis and the impact of valve size and hemodynamic parameters following aortic valve replacement (AVR) using the new Medtronic Hall Easy-Fit prosthesis. METHODS: A total of 150 patients (120 males, 30 females; mean age 62 +/- 8 years; range: 32-78 years) underwent AVR (n = 94; 63% concomitant procedures) with the Easy-Fit valve in its optimal orientation. Patients were investigated at between three and 36 months after AVR using transcranial Doppler examination of the right and left middle cerebral artery, and the incidence of HITS was determined. For evaluation of hemolysis, serum lactate dehydrogenase (LDH), hemoglobin and bilirubin were measured. These parameters were related to valve size. Transthoracic echocardiography was performed in all patients. RESULTS: Among the patients, 112 (75%) showed no or low HITS (34% none, 41% < 30/h), while only 38 (25%) had elevated HITS (range 31-100/h, 14%; range > 100/h, 11%). Statistical analysis showed a linear association between the HITS count and valve size. A positive correlation between valve size and LDH was observed; hemoglobin and bilirubin showed normal values. CONCLUSION: The valve size-dependent increase in LDH after AVR corresponds with the observation that the presence of HITS increases with valve size. In light of these findings, the surgical approach to implant the largest size Easy-Fit valve possible should be discussed, given the excellent hemodynamic results provided by the valve, even in smaller sizes.
No takes yet. Share an insight, caveat, or question.
Roland H Warnecke (2007) conducted a cohort in Aortic valve replacement (n=150). Medtronic Hall Easy-Fit heart valve prosthesis was evaluated on Incidence of high-intensity transient signals (HITS) and hemolysis. Following aortic valve replacement with the Medtronic Hall Easy-Fit prosthesis, 25% of patients had elevated HITS, and both HITS count and LDH levels positively correlated with valve size.
Synapse has enriched 10 related papers. Consider them for comparative context: