Numerical simulation demonstrates enhanced film cooling in gas turbine blades, indicating optimized hole geometry prevents flow separation.
This study numerically investigates the application of conical film cooling holes on turbine blades. Four rows of conical holes are strategically placed at critical cooling-weak regions (mid-chord/trailing edge of pressure side and leading edge of suction side) of an impingement-slot cooled blade. The effects of blowing ratio (Br), exit area ratio ( A 1 / A 2 ), and tapered section length ratio ( L E / L ) are systematically analyzed. Results demonstrate that increasing the exit area ratio enhances the film cooling effectiveness (>150 % improvement at A 1 / A 2 = 2) by reducing the jet momentum and promoting wall attachment. Optimal cooling performance is achieved at L E / L = 1/3, where vortex suppression improves coolant coverage, particularly at higher blowing ratios. Conversely, excessive expansion ( L E / L > 2/3) induces the flow separation, degrading the cooling performance. The study reveals that conical holes with moderate expansion ( A 1 / A 2 = 2 , L E / L = 1/3) achieve superior cooling effectiveness while maintaining manufacturing feasibility, providing practical insights for turbine blade cooling design.