Key result
Intraoperative high inspiratory oxygen fraction (FiO2) did not reduce the incidence of surgical site infection compared to low FiO2 during general or regional anaesthesia.
Why the study?
Controversies remain regarding optimal intraoperative FiO2, as WHO recommended 80% FiO2 to reduce surgical site infections despite data suggesting hyperoxia may have adverse effects.
Does intraoperative high FiO2 reduce surgical site infection in adult patients undergoing anaesthesia?
Systematic Review
Does intraoperative high FiO2 reduce surgical site infection in adult patients undergoing anaesthesia?
The systematic administration of high intraoperative FiO2 to decrease surgical site infections or improve perioperative outcomes is unjustified based on current evidence.
Answers are grounded in this paper and cite their sources.
High FiO2 should not be used routinely to prevent surgical site infection; challenges prior recommendations and supports standard oxygen strategies.
Despite numerous studies, controversies about the best intraoperative FiO2 remain. In 2016, the World Health Organization (WHO) recommended that adult patients undergoing general anaesthesia should be ventilated intraoperatively with an 80% FiO2 to reduce surgical site infection (SSI). However, several data suggest that hyperoxia could have adverse effects. In order to determine the potential effect of FiO2 on SSI, we included in this systematic review 23 studies (among which 21 randomised controlled trials [RCT]) published between 1999 and 2020, comparing intraoperative high versus low FiO2. Results were heterogeneous but most recent studies on one hand, and the largest RCTs on the other hand, reported no difference on the incidence of SSI regarding intraoperative FiO2 during general anaesthesia. There was also no difference in the incidence of SSI depending of intraoperative FiO2 in patients receiving regional anaesthesia. The review on secondary endpoints (respiratory and cardiovascular adverse events, postoperative nausea and vomiting, postoperative length-of-stay and mortality) also failed to support the use of high FiO2. On the opposite, some data from follow-up analyses and registry studies suggested a possible negative effect of high intraoperative FiO2 on long-term outcomes. In conclusion, the systematic administration of a high intraoperative FiO2 in order to decrease SSI or improve other perioperative outcomes seems unjustified in the light of the evidence currently available in the literature.
No takes yet. Share an insight, caveat, or question.
Fasquel et al. (2020) conducted a systematic review in Patients undergoing general or regional anaesthesia. High inspiratory oxygen fraction (FiO2) vs. Low inspiratory oxygen fraction (FiO2) was evaluated on Surgical site infection (SSI). Intraoperative high inspiratory oxygen fraction (FiO2) did not reduce the incidence of surgical site infection compared to low FiO2 during general or regional anaesthesia.
Synapse has enriched 10 related papers. Consider them for comparative context: