Key result
Four-dimensional computed tomography successfully identified prosthesis leaflet thrombosis in 1 patient with TAVR endocarditis when echocardiography was limited by prosthesis artefact.
Why the study?
Diagnosis of infective endocarditis and leaflet thrombosis after TAVR on echocardiography can be challenging due to prosthesis artefact.
Does four-dimensional computed tomography improve the diagnostic evaluation of prosthesis leaflet morphology compared to echocardiography in a patient with suspected TAVR endocarditis?
Case Report (n=1)
Does four-dimensional computed tomography improve the diagnostic evaluation of prosthesis leaflet morphology compared to echocardiography in a patient with suspected TAVR endocarditis?
Four-dimensional computed tomography provides valuable diagnostic information for assessing leaflet morphology and motion in suspected TAVR prosthetic valve endocarditis or thrombosis when echocardiography is limited by artefact.
Highlights diagnostic challenges in post-TAVR endocarditis and thrombosis; leaves open the role of advanced imaging pending larger studies.
BACKGROUND: Transcatheter aortic valve replacement (TAVR) is becoming increasingly utilized for the treatment of severe aortic valvular heart disease. Infective endocarditis of TAVR is rare but associated with higher mortality and morbidity. The potential for leaflet thrombosis following TAVR is also becoming increasingly recognized. Diagnosis of these conditions on echocardiography can be challenging due to prosthesis artefact. CASE SUMMARY: An 84-year-old man with a previous transcatheter aortic valve replacement presented with a febrile illness and bacteraemia. Transthoracic and transoesophageal echocardiography demonstrated high transvalvular gradients with features of prosthesis endocarditis, though leaflet morphology could not be fully assessed due to prosthesis artefact. Four-dimensional computed tomography revealed hypo-attenuated leaflet thickening with reduced leaflet motion, consistent with prosthesis leaflet thrombosis. The patient was successfully treated with antibiotics and anticoagulation, with resolution of the infection and normalization of the transvalvular gradient after 6 weeks. DISCUSSION: Echocardiography should be the first-line investigation for assessing leaflet morphology in suspected prosthetic valve endocarditis or leaflet thrombosis but its accuracy may be limited by artefact. Our case highlights that four-dimensional computed tomography provides further evaluation of prosthesis leaflet morphology/motion, providing valuable diagnostic information.
No takes yet. Share an insight, caveat, or question.
Khav et al. (2020) conducted a case report in Transcatheter aortic valve replacement prosthesis endocarditis with concurrent leaflet thrombosis (n=1). Four-dimensional computed tomography vs. Echocardiography was evaluated on Diagnosis of prosthesis leaflet thrombosis. Four-dimensional computed tomography successfully identified prosthesis leaflet thrombosis in 1 patient with TAVR endocarditis when echocardiography was limited by prosthesis artefact.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: