Key result
Consecutive measurements of the second systolic shoulder of the radial waveform using the OMRON HEM-9000AI device showed no significant difference (mean difference 0.3 mmHg, p=0.58), demonstrating good repeatability.
Why the study?
Does the OMRON HEM-9000AI device provide repeatable measurements of pSBP2 and pAIx in young Mexican subjects?
Observational (n=36)
No
Does the OMRON HEM-9000AI device provide repeatable measurements of pSBP2 and pAIx in young Mexican subjects?
The OMRON HEM-9000AI device demonstrates good repeatability and reliability for measuring peripheral augmentation index and radial waveform parameters in young subjects.
Answers are grounded in this paper and cite their sources.
Supports device reliability for research in young adults; leaves open clinical outcome links and broader validation.
The development of non-invasive technology to perform pulse wave analysis and accurately determine central blood pressure has facilitated the study of central blood pressure as a physiologic and biomarker parameter.Central systolic blood pressure (cSBP) has been shown to be significantly associated with adverse outcome such as mortality and associated with adverse outcome.One of the most commonly evaluated features of the arterial pressure waveforms is augmentation index (AIx).Nowadays, there are multiple devices that have been developed for calculate AIx at peripheral arteries.The aim of our study was to assess the repeatability measurements of second systolic shoulder of the radial waveform (pSBP2) and peripheral augmentation index (pAIx) using the OMRON HEM-9000AI.36 young subjects were studied.The paired t student test showed no significant difference.The mean difference between the two consecutive measures of pSBP2 was 0.3 Æ 4; P Z 0.58, pAIx (0.3 Æ 7; P Z 0.80) and pAIx75 (0.5 Æ 6.6; P Z 0.62).This study demonstrates good repeatability and reliability of this method in our study population, compared to other populations the variability between measurements.
No takes yet. Share an insight, caveat, or question.
Ramos et al. (2016) conducted an observational in Healthy subjects (n=36). OMRON HEM-9000AI device vs. Consecutive measurement was evaluated on Repeatability of second systolic shoulder of the radial waveform (pSBP2) (MD 0.3, 95% CI 0.26 to 4.3, p=0.58). Consecutive measurements of the second systolic shoulder of the radial waveform using the OMRON HEM-9000AI device showed no significant difference (mean difference 0.3 mmHg, p=0.58), demonstrating good repeatability.