Key result
Echo-colour Doppler accurately assesses right gastroepiploic artery graft patency, identifying 3 angiography-confirmed occlusions.
Why the study?
Does echo-colour Doppler accurately detect the patency of right gastroepiploic artery coronary bypass grafts?
Observational (n=113)
Does echo-colour Doppler accurately detect the patency of right gastroepiploic artery coronary bypass grafts?
Echo-colour Doppler is a safe and non-invasive method for evaluating the patency and flow capacity of right gastroepiploic artery coronary bypass grafts.
Answers are grounded in this paper and cite their sources.
May support non-invasive RGEA graft surveillance; leaves open accuracy and role before changing post-CABG practice.
The right gastroepiploic artery has been increasingly used as a coronary bypass graft. Short- and mid-term patency rates support the supposition that the right gastroepiploic artery is a satisfactory bypass conduit. However, conclusive angiographic data on long-term patency rates are still lacking. An echo-colour Doppler method was used to detect patency of the right gastroepiploic artery grafts through an upper abdominal approach. A group of 24 patients with a right gastroepiploic artery graft to the right or posterior descending coronary artery, all of whom also had a postoperative angiographic study which showed 100% patency of the graft were used as a reference group. A second group of 89 patients was also investigated only with echo-colour Doppler during the postoperative period (mean 8.0 (range 1-48) months). A patent right gastroepiploic artery graft showed a biphasic velocity pattern. Systolic peak velocity ranged from 8 to 26 cm and diastolic peak velocity from 4 to 13 cm. The right gastroepiploic artery diameter ranged from 1.7 to 2.4 mm and flow from 10.2 to 58.8 ml. Among the second group were three patients who had, at their echo-colour Doppler examination, a possible occlusion of the right gastroepiploic artery graft; an angiographic study was conducted and the graft closure confirmed in all cases. Serial echo-colour Doppler evaluation of the right gastroepiploic artery blood flow pattern and diameter is a non-invasive and safe method to check the patency and flow capacity of the artery graft in follow-up studies.
No takes yet. Share an insight, caveat, or question.
Marco Agrifoglio (1997) conducted an observational in Right gastroepiploic artery coronary bypass graft (n=113). Echo-colour Doppler evaluation vs. Angiography was evaluated on Graft patency and flow capacity. Echo-colour Doppler evaluation successfully assessed the patency of right gastroepiploic artery grafts, identifying 3 occlusions that were subsequently confirmed by angiography.
Synapse has enriched 10 related papers. Consider them for comparative context: