The effect of breathing 100 ppm of carbon monoxide versus compressed, purified air for 1 h on maximal treadmill exericse was studied (double-blind crossover design) in 10 middle-aged, healthy nonsmokers. The mean venous carboxyhemoglobin level significantly increased from 1.67% to 3.95% after breathing carbon monoxide (P less than 0.001) and significantly decreased from 1.63% to 1.30% after breathing compressed, purified air (P less than 0.001). The mean exercise time until exhaustion significantly decreased from 697.7 to 662.7 s after breathing carbon monoxide (P less than 0.001) and insignificantly increased from 694.9 s to 703.4 s after breathing compressed, purified air. Ischemic S-T segment depression larger than or equal to 1.0 mm after exercise occurred in 1 of 10 subjects after exercise following carbon monoxide inhalation. Increased carboxyhemoglobin levels of the magnitude encountered after smoking or heavy atmospheric pollution impair exercise performance in normal persons.
No takes yet. Share an insight, caveat, or question.
Wilbert S. Aronow (1975) studied this question.