Key result
Nitroglycerin is linked to ~11% higher coronary MR angiography accuracy for detecting CAD.
Why the study?
The study evaluated the influence of nitroglycerin administration on detecting significant CAD and coronary vasodilation using coronary MR angiography in patients suspected of having CAD.
Does nitroglycerin administration improve the diagnostic performance of coronary MR angiography for detecting significant coronary artery disease in patients suspected of having CAD?
Observational (n=57)
Does nitroglycerin administration improve the diagnostic performance of coronary MR angiography for detecting significant coronary artery disease in patients suspected of having CAD?
Absolute Event Rate: 87.7% vs 77.2%
p-value: p=< .001
Administration of nitroglycerin significantly improves the diagnostic accuracy and specificity of coronary MR angiography for detecting significant coronary artery disease.
Nitroglycerin may enhance coronary MR angiography accuracy for CAD detection; hypothesis-generating and requires randomized confirmation before practice change.
Purpose To evaluate the influence of applying nitroglycerin (NTG) on detecting significant coronary artery disease (CAD) and NTG-induced coronary vasodilation using coronary MR angiography in patients suspected of having CAD. Materials and Methods In this prospective study conducted from November 2017 to September 2018, 70 consecutive participants suspected of having CAD were recruited. Of those, 57 patients successfully underwent pre- and post-NTG coronary MR angiography, both of which were performed during the end-systolic phase of the cardiac cycle. Significant coronary stenosis was defined at x-ray coronary angiography as stenosis of 50% or more. Participants were divided into a significant CAD group (significant stenosis) and nonsignificant CAD group (no significant stenosis) based on x-ray coronary angiography. Paired and unpaired Student t, generalized linear mixed model, and McNemar tests were used. Results The diagnostic performance of coronary MR angiography was significantly improved after NTG (P < .001). Per-patient for coronary MR angiography, from before to after NTG, respectively, the sensitivity was 97.6% (95% confidence interval [CI]: 85.6%, 99.9%) to 97.6% (95% CI: 85.6%, 99.9%), specificity was 25.0% (95% CI: 8.3%, 52.5%) to 62.5% (95% CI: 35.9%, 83.7%), positive predictive value was 76.9% (95% CI: 62.8%, 87.0%) to 87.0% (95% CI: 73.0%, 94.6%), negative predictive value was 80.0% (95% CI: 29.9%, 98.9%) to 90.9% (95% CI: 57.1%, 99.5%), and accuracy was 77.2% (95% CI: 66.3%, 88.1%) to 87.7% (95% CI: 79.2%, 96.3%). The NTG-induced coronary vasodilation was significantly lower in the significant CAD group compared with the nonsignificant CAD group. Conclusion Administration of NTG significantly improved the diagnostic performance of coronary MR angiography for detecting significant CAD; however, NTG-induced coronary vasodilation was impaired in patients with significant CAD.
No takes yet. Share an insight, caveat, or question.
Zhao et al. (2020) conducted an observational in Coronary artery disease (n=57). Nitroglycerin vs. Pre-nitroglycerin was evaluated on Diagnostic accuracy for detecting significant coronary artery disease (p=< .001). Administration of nitroglycerin significantly improved the diagnostic accuracy of coronary MR angiography for detecting significant CAD from 77.2% to 87.7% (P<.001).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: