Self-expanding TAVR achieves ~67% device success in extremely horizontal aortas, performing best in smaller STJs.
Why the study?
Self-expanding TAVR is off-label for patients with extremely horizontal aortas (aortic angulation >=70 degrees), who are often excluded from randomized trials, leaving its feasibility unestablished.
Observational (n=27)
Self-expanding TAVR is feasible in patients with extremely horizontal aortas, particularly those with a sinotubular junction diameter ≤33.6 mm.
Self-expanding TAVR may be feasible in extremely horizontal aortas with smaller STJ; hypothesis-generating and should not yet change practice.
OBJECTIVES: To evaluate the feasibility of self-expanding transcatheter aortic valve replacement (TAVR) in patients with aortic stenosis and extremely horizontal aortas (aortic angulation ≥70°). BACKGROUND: As TAVR using a self-expanding prosthesis is an off-label treatment for patients with extremely horizontal aortas, these patients are often excluded from randomized controlled trials involving self-expanding TAVR. METHODS: This study enrolled 27 consecutive patients with extremely horizontal aortas who underwent self-expanding TAVR for severe aortic stenosis. RESULTS: The patients' average age was 76.4 years, with a median Society of Thoracic Surgeons score of 4.53%. The device success and 30-day mortality rates were 66.7% and 7.4%, respectively. The sinotubular junction (STJ) was significantly smaller in the device success group (p = 0.001). The receiver operating characteristic curve analysis found that the area under the curve was 0.907 (95% confidence interval: 0.790-1.000, p = 0.001), validating the association between STJ diameter and device success. An optimal cutoff of 33.6 mm was determined using the Youden index, with a sensitivity and specificity of 88.9% and 77.8%, respectively. The device success rate was significantly higher (93.3% vs. 33.3%, p = 0.003) in patients with STJ diameters ≤33.6 mm (n = 15). In the subgroup analyses, severe valve calcification (n = 9) was associated with a higher incidence of moderate or severe paravalvular leakage (44.0% vs. 0%, p = 0.008), while a higher rate of second valve implantation (60.0% vs. 9.1%, p = 0.030) was found in patients with less than moderate valve calcification (n = 5). CONCLUSION: Self-expanding TAVR could be suitable for patients with extremely horizontal aortas after careful preoperative evaluation.
No takes yet. Share an insight, caveat, or question.
Zhou et al. (2022) conducted an observational in Severe aortic stenosis and extremely horizontal aortas (n=27). Self-expanding transcatheter aortic valve replacement (TAVR) was evaluated on Device success. Self-expanding TAVR in patients with extremely horizontal aortas achieved a 66.7% device success rate and 7.4% 30-day mortality, with higher success (93.3%) in those with STJ diameters ≤33.6 mm.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: