Key result
Direct percutaneous transaxillary implantation of the ACURATE Neo transcatheter heart valve achieved 100% device success and 0% 30-day mortality in 12 high-risk patients with severe aortic stenosis.
Why the study?
Is direct percutaneous transaxillary implantation of the ACURATE Neo THV safe and feasible in patients with severe aortic stenosis?
Observational (n=12)
Is direct percutaneous transaxillary implantation of the ACURATE Neo THV safe and feasible in patients with severe aortic stenosis?
Direct percutaneous transaxillary implantation of the ACURATE Neo THV is technically feasible and safe, yielding excellent short-term clinical results in high-risk patients with severe aortic stenosis.
Supports transaxillary ACURATE Neo feasibility in high-risk aortic stenosis; leaves open prospective validation before practice change.
Objectives The aim of this study was to evaluate safety, feasibility, and efficacy of transaxillary TAVI using a novel self‐expandable transcatheter heart valve (THV) via a direct percutaneous technique. Methods The analysis comprises 12 consecutive patients with severe aortic stenosis treated with the ACURATE Neo™ THV (Symetis) by direct percutaneous transaxillary access. Results Patients presented with a mean age of 79.9 ± 6.2 years and high calculated surgical risk (logEuroSCORE I: 19.55 ± 15.00%; STS PROM score: 5.42 ± 3.25%). Transaxillary TAVI was performed in 11/12 via the left and in 1/12 via the right‐sided axillary artery. Device success was achieved in all patients (12/12). Mortality rate at 30 days was 0% (0/12). No major and one minor access site complication (1/12) occurred. No major or life‐threatening access site‐related bleeding resulted. None of the patients suffered from postprocedural stroke/transient ischemic attack. There was no need for a permanent pacemaker. Mean effective orifice area post implantation was 2.1 ± 0.29 cm2 and mean aortic gradient 6.2 ± 1.5 mm Hg. In none of the patients, greater than moderate aortic regurgitation or paravalvular leakage was detected at discharge (0/12). Conclusions Our study suggests that the implantation of the second‐generation self‐expandable ACURATE Neo™ via a transaxillary access is technically feasible and safe and yields excellent short‐term clinical results.
No takes yet. Share an insight, caveat, or question.
Deuschl et al. (2017) conducted an observational in severe aortic stenosis (n=12). Direct percutaneous transaxillary implantation of ACURATE Neo THV was evaluated on Device success. Direct percutaneous transaxillary implantation of the ACURATE Neo transcatheter heart valve achieved 100% device success and 0% 30-day mortality in 12 high-risk patients with severe aortic stenosis.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: