Answers are grounded in this paper and cite their sources.
We focused on the liquid hydrogen (LH2) cooled field winding superconducting generator and conducted a test to develop a liquid hydrogen cooling system for a rotor of superconducting generator. The LH2supply and exhaust system for the rotating tank which simulated the generator rotor was designed and fabricated. The rotation test was actually performed at a speed of 1800 rpm successfully and safely in a state where LH2was stored and continuously kept liquid level in the rotating tank. The rotating tank equipped with eight thermometers, two MgB2superconducting liquid level meters to know the state of liquid hydrogen in the tank. A rotation speed variation test was performed, and the behavior of the temperature and the liquid level in the rotating tank was observed. The vibrations of the rotor shaft throughout the test were within the allowable value. The experiments demonstrated the LH2cooling system of the superconducting generator rotor.
No takes yet. Share an insight, caveat, or question.
Hara et al. (2021) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: