Key result
Continuous cardiac output monitoring using the FloTrac/VigileoTM system successfully guided real-time hemodynamic management during autonomic hyperreflexia in a paraplegic woman undergoing cesarean section.
Why the study?
Paraplegic women requiring cesarean section present major challenges including cardiovascular instability induced by autonomic hyperreflexia.
Does continuous cardiac output monitoring with the FloTrac/Vigileo system improve hemodynamic management in a paraplegic woman undergoing general anesthesia for cesarean section?
Case Report (n=1)
Does continuous cardiac output monitoring with the FloTrac/Vigileo system improve hemodynamic management in a paraplegic woman undergoing general anesthesia for cesarean section?
Continuous hemodynamic monitoring with the FloTrac/Vigileo system can aid in managing autonomic hyperreflexia and maintaining hemodynamic stability during general anesthesia for cesarean section in paraplegic patients.
Answers are grounded in this paper and cite their sources.
Case report suggests feasibility of FloTrac-guided management; leaves open whether routine use improves outcomes in paraplegic cesarean deliveries.
Rationale: Paraplegic women requiring cesarean section present plenty of challenges for anesthesiologists. One of the most serious challenges is cardiovascular instability induced by autonomic hyperreflexia. The FloTrac/Vigileo TM system is a pulse contour analysis device for continuous hemodynamic index monitoring. Here, we present a case report of a paraplegic woman who underwent general anesthesia for cesarean section under FloTrac/VigileoTM monitoring. Patient concerns: A 33-year-old paraplegic woman was scheduled for cesarean section at the 38th week of gestation. The woman was completely paralyzed below T4 after a surgical treatment for a spinal cord bulge at the neck-chest junction. Diagnoses: A paraplegic G1 P0 patient at 38 week gestation following in-vitro fertilization and embryo transfer requiring elective cesarean section. Interventions: We chose general anesthesia for the patient under FloTrac/VigileoTM system monitoring. In accordance with the FloTrac/VigileoTM system monitoring, vasoactive drugs and liquid infusion were adjusted in real time. Outcomes: Autonomic hyperreflexia emerged during the surgery and the patient was treated in a timely manner because of the FloTrac/VigileoTM system. There were no complications, and the patient delivered a healthy baby girl. Lessons: Paraplegic women can be treated with general anesthesia under FloTrac/VigileoTM system monitoring. The FloTrac/VigileoTM system monitoring can be used to help monitor and maintain a paraplegic patient's hemodynamic stability.
No takes yet. Share an insight, caveat, or question.
Li et al. (2021) conducted a case report in Paraplegia requiring cesarean section (n=1). FloTrac/VigileoTM system monitoring during general anesthesia was evaluated on Hemodynamic stability and complications. Continuous cardiac output monitoring using the FloTrac/VigileoTM system successfully guided real-time hemodynamic management during autonomic hyperreflexia in a paraplegic woman undergoing cesarean section.
Synapse has enriched 10 related papers. Consider them for comparative context: