Key result
An ECG-based risk score from sinus rhythm predicts AF development with ~0.76 AUC.
Why the study?
Early prediction of AF development would improve patient outcomes, motivating the development of a simple and cheap ECG-based score to predict AF development.
Does an automated ECG-based risk score predict the development of atrial fibrillation in patients with sinus rhythm?
Cohort (n=16,316)
Does an automated ECG-based risk score predict the development of atrial fibrillation in patients with sinus rhythm?
Effect estimate: AUC 0.764 (95% CI 0.722 to 0.806)
An automated risk score utilizing standard sinus rhythm ECG biomarkers can predict the future development of atrial fibrillation with moderate accuracy, offering a potential low-cost screening tool.
May enable ECG-based AF risk stratification in sinus rhythm; leaves open prospective validation before clinical adoption.
OBJECTIVE: Early prediction of atrial fibrillation (AF) development would improve patient outcomes. We propose a simple and cheap ECG based score to predict AF development. METHODS: A cohort of 16 316 patients was analysed. ECG measures provided by the computer-assisted ECG software were used to identify patients. A first group included patients in sinus rhythm who showed an ECG with AF at any time later (n=505). A second group included patients with all their ECGs in sinus rhythm (n=15 811). By using a training set (75% of the cohort) the initial sinus rhythm ECGs of both groups were analysed and a predictive risk score based on a multivariate logistic model was constructed. RESULTS: A multivariate regression model was constructed with 32 variables showing a predictive value characterised by an area under the curve (AUC) of 0.776 (95% CI: 0.738 to 0.814). The subsequent risk score included the following variables: age, duration of P-wave in aVF, V4 and V5; duration of T-wave in V3, mean QT interval adjusted for heart rate, transverse P-wave clockwise rotation, transverse P-wave terminal angle and transverse QRS complex terminal vector magnitude. Risk score values ranged from 0 (no risk) to 5 (high risk). The predictive validity of the score reached an AUC of 0.764 (95% CI: 0.722 to 0.806) with a global specificity of 61% and a sensitivity of 55%. CONCLUSIONS: The automatic assessment of ECG biomarkers from ECGs in sinus rhythm is able to predict the risk for AF providing a low-cost screening strategy for early detection of this pathology.
No takes yet. Share an insight, caveat, or question.
Sanz‐García et al. (2021) conducted a cohort in Atrial fibrillation (n=16,316). ECG-based risk score was evaluated on Prediction of atrial fibrillation development (AUC 0.764, 95% CI 0.722 to 0.806). An ECG-based risk score using biomarkers from sinus rhythm ECGs predicted the development of atrial fibrillation with an AUC of 0.764 (95% CI 0.722 to 0.806).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: