By the application of film cooling in addition to regenerative cooling, a considerable reduction in thermal and structural loads of rocket combustion-chamber walls can be reached. This paper discusses important influence parameters on film cooling in terms of efficiency of the injected film and wall temperature reduction. For the experimental investigations a high-pressure subscale combustion chamber operated with the cryogenic propellant combination LOX=GH2 was used. A gaseous film with ambient tempered hydrogen was injected in the axial direction at the face plate. Typical film-cooling parameters such as film blowing rate, velocity ratio between film injection velocity and hot-gas velocity, circumferential slot positioning, and film injection slot height were investigated systematically at the European Research and Technology Test Facility P8.
No takes yet. Share an insight, caveat, or question.
Arnold et al. (2010) studied this question.
Synapse has enriched one closely related paper. Consider it for comparative context: