Key result
Atrial antitachycardia pacing terminates ~63% of slow atrial tachycardia episodes in complex congenital heart disease.
Why the study?
Does a pacemaker atrial antitachycardia pacing algorithm terminate slow atrial tachycardia with 1:1 atrioventricular conduction in a patient with complex congenital heart disease?
Case Report (n=1)
Does a pacemaker atrial antitachycardia pacing algorithm terminate slow atrial tachycardia with 1:1 atrioventricular conduction in a patient with complex congenital heart disease?
Atrial antitachycardia pacing can successfully terminate relatively slow atrial tachycardia with 1:1 AV conduction in patients with complex congenital heart disease when catheter ablation is unsuccessful.
A transvenous dual-chamber pacemaker successfully terminated relatively slow atrial tachycardia with 1:1 atrioventricular conduction using atrial antitachycardia pacing after unsuccessful catheter ablation in a patient with complex congenital heart disease.
No takes yet. Share an insight, caveat, or question.
Toyohara et al. (2026) conducted a case report in Slow atrial tachycardia with 1:1 AV conduction in complex congenital heart disease (n=1). Transvenous dual-chamber pacemaker with atrial antitachycardia pacing was evaluated on Successful termination of atrial tachycardia by atrial antitachycardia pacing. Atrial antitachycardia pacing successfully terminated 63% of slow atrial tachycardia episodes with 1:1 AV conduction over a 3-year follow-up in a patient with complex congenital heart disease.