Key result
Continuous wave Doppler reveals alternating high-intensity diastolic and low-intensity systolic signals in cor triatriatum.
Case Report (n=1)
Continuous wave Doppler can provide complementary haemodynamic information in the echocardiographic diagnosis of cor triatriatum.
Answers are grounded in this paper and cite their sources.
May complement echo diagnosis of cor triatriatum; leaves open generalizability from single case report.
Continuous wave Doppler recordings of the turbulent jet through the restrictive orifice of a left atrial partition in a patient with corrected transposition of the great arteries and cor triatriatum showed alternate bands of high intensity diastolic and low intensity systolic signals with preservation of the normal configuration of the diastolic E and A peaks. It is thought that Doppler studies in cor triatriatum will provide useful complementary haemodynamic information in the echocardiographic diagnosis of this anomaly.
No takes yet. Share an insight, caveat, or question.
Alwi et al. (1992) conducted a case report in Corrected transposition of the great arteries and cor triatriatum (n=1). Continuous wave Doppler echocardiography was evaluated on Doppler signal characteristics. Continuous wave Doppler recordings in a patient with cor triatriatum demonstrated alternate bands of high intensity diastolic and low intensity systolic signals with preserved E and A peaks.