Key result
Next-generation transapical TAVI achieves ~97% procedural success in high-risk patients.
Why the study?
Does transapical TAVI with next-generation devices improve short-term outcomes in high surgical risk patients with aortic stenosis?
Cohort (n=200)
No
Does transapical TAVI with next-generation devices improve short-term outcomes in high surgical risk patients with aortic stenosis?
Next-generation transapical TAVI devices demonstrate high procedural success, positive hemodynamic results, and low rates of relevant paravalvular regurgitation in high-risk patients with aortic stenosis.
Answers are grounded in this paper and cite their sources.
May support next-generation transapical TAVI in selected high-risk patients; extends observational data but leaves open randomized confirmation.
OBJECTIVES: Transcatheter aortic valve implantation (TAVI) has become an established procedure in patients with aortic stenosis and high surgical risk. Experience with first-generation transcatheter heart valves (THVs) is broad but limitations, e.g. paravalvular regurgitation, have been demonstrated. Much hope rests on the recently Conformité Européenne mark approved next-generation devices to improve results in these patients. However, apart from the initial approval studies, clinical data with these new devices are still scarce. We aimed to assess short-term outcomes of 200 consecutive patients who underwent transapical TAVI with next-generation THV at our institution. METHODS: Transapical TAVI was performed in 200 consecutive patients 80.5±6.7 years old (38.5% female) at high surgical risk (log EuroSCORE 20.2±16.5%). Devices implanted were the Engager (Medtronic, Inc., Minneapolis, MN, USA; n=50), JenaValve (JenaValve Technology, Munich, Germany; n=88) and Symetis Acurate (Symetis SA, Ecublens, Switzerland; n=62) THV that were selected by the heart team on an individual basis. Data at baseline, during the procedure and follow-up were analysed according to standardized Valve Academic Research Consortium end points. Median follow-up was 219 days. RESULTS: Implantation was successful in 96.5% of cases. Valve function improved significantly with an increase in effective orifice area from 0.8±0.4 to 1.8±0.3 cm2 and a reduction in mean transvalvalvular gradients from 34.0±17.0 to 11.2±5.4 mmHg. Paravalvular regurgitation was none or trace in 70.3% of patients, Grade 1 in 26.1%, and Grade 2 in 3.5%. No patients developed aortic regurgitation>Grade 2. Major access site complications occurred in 6.5%, major stroke in 1.5% and stage-3 kidney injury in 2.5% of patients. A permanent pacemaker was implanted in 20.5% of patients overall and in 8.0% for a complete heart block. At 30-day follow-up 72.8% of patients were in New York Heart Association class I or II (10.5% at baseline). Overall survival was 91.5% at 30 days and 73.9% at 1 year. CONCLUSIONS: In a real-world clinical setting, next-generation transapical THV yielded positive haemodynamic results. The incidence of relevant paravalvular regurgitation was scarce in this group and clinical outcomes were encouraging during short-term follow-up. Long-term follow-up is required to investigate the durability of these new devices.
No takes yet. Share an insight, caveat, or question.
Seiffert et al. (2014) conducted a cohort in aortic stenosis (n=200). Transapical TAVI with next-generation THV was evaluated on Successful implantation. Transapical TAVI with next-generation devices in high-risk patients achieved a 96.5% procedural success rate, with 30-day and 1-year overall survival rates of 91.5% and 73.9%, respectively.
Synapse has enriched 10 related papers. Consider them for comparative context: