Key result
Quantified stress long-axis function identifies CAD in dilated cardiomyopathy with ~85% sensitivity, beating standard WMSI.
Why the study?
Does quantified long-axis function during dobutamine stress echocardiography improve the detection of CAD compared to standard WMSI in patients with dilated cardiomyopathy?
Observational (n=73)
Does quantified long-axis function during dobutamine stress echocardiography improve the detection of CAD compared to standard WMSI in patients with dilated cardiomyopathy?
Quantified stress long-axis function during dobutamine echocardiography identifies CAD in dilated cardiomyopathy with greater accuracy than standard WMSI, especially in patients with LBBB.
Answers are grounded in this paper and cite their sources.
Supports further study of quantified long-axis function in DCM stress echo; hypothesis-generating and should not yet change practice.
BACKGROUND: Resting regional wall-motion abnormalities do not reliably distinguish ischemic from nonischemic cardiomyopathy. Dobutamine stress echocardiography with use of the wall-motion score index (WMSI) identifies coronary artery disease (CAD) in dilated cardiomyopathy (DCM), but the technique is subjective and further complicated by left bundle-branch block (LBBB). Long-axis motion is sensitive to ischemia and can be assessed quantitatively. We aimed to compare long-axis function with WMSI for detecting CAD in DCM with or without LBBB. METHODS AND RESULTS: Seventy-three patients with DCM, 48 with CAD (16 with LBBB), and 25 without CAD (10 with LBBB) were studied. Long-axis M-mode, pulsed-wave tissue Doppler echograms (lateral, septal, and posterior walls), and WMSI were assessed at rest and at peak dobutamine stress. Failure to increase systolic amplitude (total amplitude minus postejection shortening) by 2 mm or early diastolic velocity by 1.1 cm/s was the best discriminator for CAD (systolic amplitude, sensitivity 85%, specificity 86%; lengthening velocity, 71% and 94%, respectively; P=NS). Both had greater predictive accuracy than did WMSI (sensitivity 67%, specificity 76%; P<0.001). The predictive accuracy of changes in septal long-axis function was similar to those of average long-axis function (systolic amplitude cutoff=1.5 mm, lengthening velocity cutoff=1.5 cm/s). However in LBBB, systolic amplitude proved to be the only significant discriminator for CAD, with sensitivity and specificity reaching 94% and 100%, respectively (P<0.01 versus early diastolic lengthening velocity). CONCLUSIONS: Quantified stress long-axis function identifies CAD in DCM with greater sensitivity and specificity than does standard WMSI, particularly in the presence of LBBB.
No takes yet. Share an insight, caveat, or question.
Duncan et al. (2003) conducted an observational in Dilated cardiomyopathy with or without coronary artery disease and left bundle-branch block (n=73). Long-axis function assessment during dobutamine stress echocardiography vs. Wall-motion score index (WMSI) was evaluated on Detection of coronary artery disease (CAD) (p=<0.001). Quantified stress long-axis function identified CAD in dilated cardiomyopathy with greater sensitivity and specificity than standard WMSI.
Synapse has enriched 10 related papers. Consider them for comparative context: