Key result
Bovine red cells maintain mechanical and energetic stability in isolated rabbit hearts for ~60 minutes.
The isolated bovine red cell-perfused rabbit heart preparation maintains mechanical and energetic stability for at least 60 minutes, validating its use in short-term physiological studies.
Answers are grounded in this paper and cite their sources.
Supports short-term use of this preparation in isolated-heart research; leaves open questions on stability beyond 60 minutes.
We evaluated the mechanical and energetic stability of the isolated rabbit heart perfused with a suspension of bovine red cells in Krebs-Henseleit buffer in terms of the pressure-volume area (PVA) concept. PVA, the area surrounded by the end-systolic and end-diastolic pressure-volume (P-V) relations and the systolic P-V trajectory of the P-V diagram, represents the total mechanical energy generated by each cardiac contraction. Myocardial O2 consumption (VO2) per beat has been reported to be highly linearly correlated with PVA. We used the slope and VO2-axis intercept of the VO2-PVA relation as energetic parameters and the maximum P-V ratio (Emax) as a contractility index of the left ventricle (LV) and compared them every 30 min for 120 min. Emax, the slope, and VO2 intercept of the VO2-PVA relation did not change significantly over 120 min compared with their control values [7.3 +/- 2.9 mmHg.ml-1.100 g LV, (1.67 +/- 0.40) x 10(-5) ml O2.mmHg-1.ml-1, and (3.26 +/- 1.01) x 10(-2) ml O2.beat-1.100 g LV-1, respectively]. However, the goodness of the linear fit of the VO2-PVA relation decreased after 90 min (r = 0.94 control, 0.62 at 90 min, and 0.64 at 120 min). Therefore, we conclude that the isolated bovine red cell-perfused rabbit heart preparation is stable for mechanical and energetic studies for at least 60 min.
No takes yet. Share an insight, caveat, or question.
Yaku et al. (1991) studied Isolated rabbit heart preparation. Perfusion with bovine red cells in Krebs-Henseleit buffer vs. Baseline/control values was evaluated on Mechanical and energetic stability (Emax, slope, and VO2 intercept of the VO2-PVA relation) (p=NS). In isolated rabbit hearts perfused with bovine red cells, mechanical and energetic parameters remained stable for at least 60 minutes, though the linear fit of the VO2-PVA relation decreased after 90 minutes.
Synapse has enriched 10 related papers. Consider them for comparative context: