Key result
External carotid pulse closely tracks carotid pressure throughout systole in aortic valve disease.
Why the study?
Do external carotid pulse recordings accurately reflect central aortic and carotid pressure pulses in patients with aortic valve disease?
Observational (n=5)
Do external carotid pulse recordings accurately reflect central aortic and carotid pressure pulses in patients with aortic valve disease?
External carotid pulse recordings closely reflect the carotid pressure pulse in patients with aortic valve disease, supporting their use as a non-invasive guide to central hemodynamics.
May support external carotid recordings as noninvasive central pressure surrogate in aortic valve disease; hypothesis-generating given small cross-sectional sample.
As it passes from the proximal aorta to the periphery, the normal pulse undergoes striking changes, mainly due to peripheral reflections, which result in it becoming sharper and increased in amplitude (Kroeker and Wood, 1955; McDonald and Taylor, 1959).The abnormal pulse is also subject to change, and alterations in the central pulse may, as a result, become either more or less obvious in the periphery.Thus the characteristic pulse of aortic regurgitation is made more obvious by transmission (Wright and Wood, 1958).The typical central pulse of aortic stenosis, on the other hand, may be so altered by transmission that the brachial fails to show a diagnostic pattern (Hancock and Fleming, 1960).As a result of the inadequacy of the brachial pulse in diagnosis, the carotid pulse, recorded by external means, is now increasingly used as a guide to central events (Duchosal et al., 1956; Daoud, Reppert, and Butterworth, 1959; Robinson, 1963).The present study is an attempt to assess how closely external carotid tracings reflect the central aortic pulse and in what ways they are superior to brachial pulse recordings.The relation of external carotid tracings to simultaneous carotid pressure recordings will first be established, and various types of external carotid will then be compared with the aortic and brachial pulse. RESULTSRelation ofExternal Carotid to Carotid I 'ssure Pulse.In all 5 patients with aortic valve disease, the external pulse followed the pressure pulse closely throughout systole (Fig. 1, A, B, and C); in 61 on November 22, 2023 by guest.
No takes yet. Share an insight, caveat, or question.
Bradley W. Robinson (1963) conducted an observational in Aortic valve disease (n=5). External carotid tracings vs. Carotid pressure recordings was evaluated on Relation of external carotid to carotid pressure pulse. In 5 patients with aortic valve disease, the external carotid pulse followed the carotid pressure pulse closely throughout systole.
Synapse has enriched 3 closely related papers on similar clinical questions. Consider them for comparative context: