Key result
Starr-Edwards cloth-covered steel ball prosthesis yields ~64% seven-year survival for aortic valve replacement.
Cohort (n=1,375)
No
The Starr-Edwards cloth-covered steel ball prosthesis demonstrated acceptable long-term survival and freedom from thromboembolism, with very low rates of clinically significant cloth-wear.
Historical benchmarks from early mechanical valves inform durability expectations; leaves open relevance to contemporary prostheses in modern cohorts.
The two principal considerations with prosthetic valves are durability and thromboembolism. With the widespread interest in recently developed prosthetic valves (porcine, tilting disc, Cooley), the long-term results at one institution with a single prosthesis were considered of particular importance. Accordingly, a 97% follow-up has been completed on 1375 patients (pts) undergoing prosthetic valve replacement with the Starr-Edwards cloth-covered steel ball prosthesis at New York University between October 1967 and December 1975. Operative procedures were as follows: aortic valve replacement (AVR): 470 pts; mitral valve replacement (MVR): 362 pts; combined AVR and MVR: 129 pts; other combined procedures: 414 pts. Overall operative deaths were 13.7%, 9% for AVR, 10.8% for MVR, and 18.6% for combined AVR and MVR. At seven years, AVR survival was 64%, and MVR survival 64.5%. There has been widespread pessimism, usually without significant data, about the cloth-covered prosthesis, because of concern of cloth wear, hemolysis and other complications. Therefore, a particularly significant finding by actuarial analysis was that 85% of surviving patients with isolated AVR remained free of emboli for five years. In pts surviving isolated MVR, 80% remained free of emboli for five years. Of those having embolic episodes, 33% were not on anticoagulants. Fatal hemorrhage from anticoagulants occurred in 0.8% of pts. Endocarditis occurred in 5.7% of the entire group, with 1.3% requiring reoperation. Clinically significant hemolysis occurred in 5.1% of the group, with only 0.2% requiring reoperation. Hence, the total frequency of clinically significant cloth-wear was less than 0.5%. These data indicate both the reliability and the limitations of the Starr-Edwards cloth-covered steel ball valve and can be used in comparing experiences with the more recently developed prostheses.
No takes yet. Share an insight, caveat, or question.
Isom et al. (1977) conducted a cohort in Valvular heart disease requiring replacement (n=1,375). Starr-Edwards cloth-covered steel ball prosthesis was evaluated on Overall operative deaths. Valve replacement with the Starr-Edwards cloth-covered steel ball prosthesis resulted in an overall operative mortality of 13.7% and a 7-year survival of 64% for aortic valve replacement.
Synapse has enriched 2 closely related papers on similar clinical questions. Consider them for comparative context: