Key result
Continuous suture technique yields similar mean gradients to interrupted technique for Pericarbon Freedom stentless valves.
Why the study?
Does a continuous suture technique compared to an interrupted suture technique improve postoperative hemodynamics in patients receiving the Pericarbon Freedom stentless valve?
Cohort (n=139)
Does a continuous suture technique compared to an interrupted suture technique improve postoperative hemodynamics in patients receiving the Pericarbon Freedom stentless valve?
The continuous suture technique for the Pericarbon Freedom stentless valve reduces bypass and cross-clamping times without compromising postoperative hemodynamics compared to the interrupted technique.
Continuous suture may be used without hemodynamic compromise; leaves open randomized confirmation of shorter operative times.
BACKGROUND: The Pericarbon Freedom stentless valve has shown excellent hemodynamic results in the midterm course. However, there is no information as to whether a continuous or interrupted suture technique at the inflow site has an impact on postoperative hemodynamics. METHODS: 139 patients were enrolled in a non-randomized, prospective matched trial. An interrupted suture line technique was used in 68 patients and a continuous suture line technique was used in 71 at the inflow site. Isolated valve replacement was performed in 70.4% of the continuous and 67.6% of the interrupted suture group. Pre- and postoperative hemodynamics and one-year follow-up were obtained by echocardiography and expressed as mean and peak gradients and grade of regurgitation. RESULTS: No significant difference between continuous and interrupted suture techniques were noted with respect to mean (11.8 +/- 6.3 vs. 12.5 +/- 6.2 mm Hg, p = 0.251) and peak gradients (21.0 +/- 9.6 vs. 22.0 +/- 10.9 mm Hg, p = 0.292) as well as to the degree of regurgitation. Bypass and cross-clamping times decreased by 22.4 and 20.6 minutes, respectively, with the use of the continuous suture technique. One year follow-up showed a further, significant decrease of mean and peak gradients. CONCLUSIONS: The Pericarbon Freedom stentless valve appears to offer excellent postoperative performance. The suture line technique at the inflow site does not result in any hemodynamic differences.
No takes yet. Share an insight, caveat, or question.
Beholz et al. (2005) conducted a cohort in Valve replacement (n=139). Continuous suture line technique vs. Interrupted suture line technique was evaluated on Mean gradient (p=0.251). A continuous suture line technique for the Pericarbon Freedom stentless valve yielded similar mean gradients compared to an interrupted technique (11.8 vs. 12.5 mm Hg, p=0.251).