Key result
Adding pulse wave upstroke time to inter-arm systolic pressure difference boosts subclavian stenosis sensitivity to ~85%.
Why the study?
Subclavian artery stenosis is often asymptomatic with disastrous consequences, and traditional screening methods remain unsatisfactory.
Does the combination of inter-arm systolic pressure difference and pulse volume recording derivatives improve the detection of subclavian artery stenosis in patients suspected of supra-arch artery stenosis?
Observational (n=320)
No
Does the combination of inter-arm systolic pressure difference and pulse volume recording derivatives improve the detection of subclavian artery stenosis in patients suspected of supra-arch artery stenosis?
Combining inter-arm systolic pressure difference with pulse volume recording derivatives improves diagnostic sensitivity for detecting subclavian artery stenosis compared to using inter-arm systolic pressure difference alone.
Answers are grounded in this paper and cite their sources.
May aid noninvasive subclavian stenosis detection; leaves open prospective validation before practice change.
Background Subclavian artery stenosis (SAS) is a peripheral arterial disease of asymptomatic appearance and disastrous consequences. The traditional screening method remains unsatisfactory. Objective The study aimed to assess the diagnostic performances of inter-arm systolic pressure difference (IASBPD), derivatives of pulse volume recording (PVR), and their combination in detecting subclavian artery stenosis. Materials and methods The present study was a retrospective analysis of clinical data from inpatients suspected of supra-arch artery stenosis in Fuwai hospital during 1 year, who underwent selective arterial angiographies. We obtained simultaneous blood pressure measurements on four limbs and pulse waves for calculating IASBPD and PVR derivatives prior to the angiographies. We utilized the receiver operating characteristic curve (ROC) to calculate the optimal cut-off value of IASBPD, upstroke time (UT), and upstroke time per cardiac cycle (UTCC) for detecting SAS. Moreover, we compared the sensitivity and specificity of IASBPD, UT, UTCC, and their combinations for diagnosing SAS (Clinical trial number: NCT03521739). Results We consecutively enrolled 320 eligible patients. Based on SAS’s definition of stenosis above 50%, the area under the curve of IASBPD, UT, and UTCC were 0.84, 0.76, and 0.80 (P < 0.001). And their corresponding cut-off points were 9 mmHg, 202 milliseconds, and 23.2%. The sensitivity and specificity of IASBPD ≥ 9 mmHg were 57.0 and 94.1%. UT ≥ 202 ms and UTCC ≥ 23.2% yielded similar sensitivity (72.6 vs. 72.6%, P > 0.05), but UTCC had higher specificity (81.1 vs. 72.4%, P < 0.05). The sensitivity of the combination of IASBPD and UT (85.2%) or UTCC (78.5%) was significantly higher than IASBPD alone (57%, P < 0.05). The specificity of either combination decreased to 67.6 and 76.8% (P < 0.05). Conclusions This present study showed that the combinations of IASBPD and PVR-derived parameters promoted diagnostic sensitivity and preserved adequate specificity than those alone for detecting SAS.
No takes yet. Share an insight, caveat, or question.
An et al. (2022) conducted an observational in Subclavian artery stenosis (n=320). Combination of inter-arm systolic pressure difference (IASBPD) and pulse wave upstroke time (UT) vs. IASBPD alone was evaluated on Sensitivity for detecting subclavian artery stenosis ≥50% (p=<0.05). Combining inter-arm systolic pressure difference with pulse wave upstroke time significantly improved diagnostic sensitivity for detecting subclavian artery stenosis to 85.2% compared to 57.0% for inter-arm systolic pressure difference alone.