Key result
Combined 6 Fr Diaventional catheter achieves ~94% procedural success for coronary restenosis.
Why the study?
Is the systematic use of a combined diagnostic and interventional 6 Fr guide catheter feasible and successful for re-PTCA in patients with suspected coronary restenosis?
Observational (n=80)
Is the systematic use of a combined diagnostic and interventional 6 Fr guide catheter feasible and successful for re-PTCA in patients with suspected coronary restenosis?
The systematic use of a 6 Fr combined diagnostic and interventional catheter for coronary restenosis is highly feasible, achieving a 94% success rate while reducing procedural costs.
Supports single-catheter strategy for restenosis; hypothesis-generating and requires randomized confirmation before practice change.
This prospective study assessed the feasibility of re‐percutaneous transluminal coronary angioplasty for coronary restenosis using routinely the new 6 Fr diagnostic/interventional Diaventional catheter with a large internal lumen (0.057) in 80 consecutive patients. Two patients had restenosis on two vessels. The restenosed coronary artery more frequently was the left anterior descending coronary artery (52%). In the first six patients, the over‐the‐wire technique was used; in the other patients, we used a balloon‐on‐a‐wire device or a rapid‐exchange balloon catheter. With these latter techniques, angiographic visualization was satisfactory, even when the balloon was placed through the stenosis. The balloon size varied from 2.0‐3.5 mm (mean 2.9 ± 0.4 mm). In two patients, an immediate recoil needed reintervention with the same equipment and yielded a satisfactory final result. All but one procedure (81/82) were successful (in one patient, a total chronic occlusion could only transiently be reopened). However, in four patients, a complementary 6 Fr or 8 Fr technique, using standard guiding catheters, had to be used for a large dissection (two patients) and for failure to cross a tight stenosis (two patients). The overall success rate was 94% (77/82), with a 9.2% reduction of the total cost of the invasive procedure. In coronary restenosis, the use of the new 6 Fr diagnostic/interventional Diaventional catheter is possible with an excellent overall success rate and a reduction of the total cost of the invasive procedure.
No takes yet. Share an insight, caveat, or question.
Juillière et al. (1997) conducted an observational in Coronary restenosis (n=80). 6 Fr diagnostic/interventional Diaventional catheter was evaluated on Overall success rate. The systematic use of a combined diagnostic and interventional 6 Fr Diaventional catheter for coronary restenosis was feasible, achieving an overall success rate of 94% (77/82 procedures).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: