Key result
Hemoglobin changes inversely correlate with diastolic PAP changes in ambulatory HF patients, particularly at hospitalization.
Why the study?
While haemoconcentration measures correlate with invasive haemodynamics in hospitalized HF patients, their association in ambulatory patients with implantable PAP sensors is unknown.
Cohort (n=23)
No
Effect estimate: r = -0.09
p-value: p=0.053
Changes in haemoglobin inversely correlate with changes in diastolic pulmonary artery pressure in ambulatory heart failure patients, suggesting haemoglobin could serve as a non-invasive marker to guide decongestion.
Haemoglobin changes associate with diastolic PAP shifts in ambulatory HF; hypothesis-generating and requires prospective validation before clinical use.
AIMS: Laboratory measures of haemoconcentration correlate with invasive haemodynamics and clinical outcomes in hospitalized heart failure (HF) patients. We aimed to determine the association between haemoconcentration and haemodynamic measures in ambulatory HF patients with implantable pulmonary arterial pressure (PAP) sensors. METHODS AND RESULTS: We reviewed ambulatory HF patients (n = 23) managed at the Brigham and Women's Hospital with implantable PAP sensors (CardioMEMS™, Abbott, Atlanta, GA, USA) who had sufficient data for serial haemodynamic-haemoconcentration correlation. The primary measures of interest were the absolute changes in haemoglobin and diastolic PAP at follow-up compared to baseline values (obtained at implantation). In 23 patients (median age 64 years, 57% with HF with preserved ejection fraction), 518 paired laboratory-haemodynamic measurements were evaluated. At a median follow-up of 27 (interquartile range 13-42) months, 17 (74%) patients had at least one hospitalization (59 total hospitalizations including 30 HF hospitalizations). For the population as a whole, diastolic PAP was negatively correlated with haemoglobin level (r = -0.09, P = 0.053). This negative correlation was more apparent when changes in haemoglobin and diastolic PAP were evaluated at the time of HF hospitalization compared to baseline values (r = -0.40, P = 0.029). The mean rise in diastolic PAP of 3.6 mmHg at HF hospitalization corresponded to a numerical decline of 0.6 g/dL in haemoglobin (P = 0.20). CONCLUSION: Change in haemoglobin was correlated with change in diastolic PAP in ambulatory HF patients, especially at the time of HF hospitalization. These findings support the potential for investigation into the role of ambulatory monitoring of haemoglobin as an inexpensive, non-invasive tool to guide de-congestion strategies and potentially prevent HF hospitalizations.
No takes yet. Share an insight, caveat, or question.
Almufleh et al. (2020) conducted a cohort in Ambulatory heart failure (n=23). Haemoconcentration (haemoglobin level) vs. Baseline values was evaluated on Absolute changes in haemoglobin and diastolic pulmonary arterial pressure at follow-up compared to baseline values (r = -0.09, p=0.053). Changes in haemoglobin levels were negatively correlated with changes in diastolic pulmonary arterial pressure in ambulatory heart failure patients, particularly at hospitalization (r=-0.40, P=0.029).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: