Key result
Hankel-SVD filter achieves ~9 dB power separation between blood and moving tissue vs clutter-downmixing filter.
Population
Synthetic slow-time data modeling arterial and deep vessel imaging, and in vivo color flow data from human…
Comparison
Hankel-SVD filter vs Clutter-downmixing filter and a fixed-rank multi…
Design
Other
Authors
Loading...
May enhance experimental clutter suppression in color flow imaging; leaves open clinical diagnostic gains pending validation.
Absolute Event Rate: 9% vs 2.5%
The proposed Hankel-SVD filter improves clutter suppression and better distinguishes between blood and moving tissue in color flow ultrasound imaging compared to existing filters.
Yu et al. (2008) studied this question. Hankel-SVD filter vs. clutter-downmixing filter and fixed-rank multi ensemble-based eigen-filter was evaluated on Separation in power between blood and moving-tissue regions. The Hankel-SVD filter achieved better distinction between blood and moving-tissue regions (about 9 dB separation in power) compared to the clutter-downmixing filter (2 to 3 dB separation).