PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
December 2, 2025Heart Failure Reviews2 citationsOpen Access

Toward next-generation BNP/NT-proBNP biosensors: multiplexed detection, biofouling control, and digital health integration

View Full Paper
AEAdnan ElahiPSPatricia Scully

Key Result

Recent advances in BNP/NT-proBNP biosensors achieve femtogram-to-picogram limits of detection, though gaps remain between laboratory performance and clinical implementation.

PICO

P
Population
Heart Failure
I
Intervention / Comparator
BNP/NT-proBNP biosensors

Limitations

  • Gaps between laboratory performance and clinical implementation

Abstract

In the past five years, rapid progress has been made in biosensor platforms for BNP and NT-proBNP detection. Innovations span fluorescence-based assays (FRET aptasensors, quantum dots, NIR persistent luminescence probes), colorimetric nanozyme-enhanced lateral flow assays, surface-enhanced Raman scattering (SERS) systems and electrochemiluminescence immunoassays. These strategies exploit advances in nanomaterials, photonic engineering, and biointerface design to achieve femtogram-to-picogram limits of detection, multiplex biomarker analysis, and smartphone-compatible readouts. Parallel work on biofouling mitigation through zwitterionic coatings, hydrogel nanocomposites, and MOF encapsulation can be adapted for further enhance sensor robustness in complex biological fluids. This review critically evaluates BNP/NT-proBNP detection technologies reported between 2020 and 2025, comparing analytical performance, material design, and translational potential. We highlight gaps between laboratory performance and clinical implementation, discuss harmonisation with established commercial assays, and outline future directions in multiplexed panels, wearable monitoring, and digital health integration. By synthesizing recent advances, this work provides a roadmap toward biosensors capable of transforming HF care through earlier diagnosis, decentralised testing, and proactive disease management.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Elahi et al. (2025) conducted a review in Heart Failure. BNP/NT-proBNP biosensors was evaluated. Recent advances in BNP/NT-proBNP biosensors achieve femtogram-to-picogram limits of detection, though gaps remain between laboratory performance and clinical implementation.

synapsesocial.com/papers/6aa4f8a13a03b8d03ddc3e14https://doi.org/10.1007/s10741-025-10573-4
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1NT-proBNP detection with a one-step magnetic lateral flow channel assay2024 · 9 citations
  2. 2A review on B-type natriuretic peptide monitoring: assays and biosensors2016 · 84 citations
  3. 3A comparison of the prognostic value of BNP versus NT-proBNP after hospitalisation for heart failure2018 · 22 citations
  4. 4Recent Advances in Hydrogel-Promoted Photoelectrochemical Sensors2025 · 9 citations
  5. 52021 ESC Guidelines for the Diagnosis and Treatment of Acute and Chronic Heart Failure2022 · 2,216 citations