Key result
Direct ascending aortic Impella CP rescues a patient from complete circulatory collapse during transaortic TAVR.
Population
1 patient undergoing transaortic transcatheter aortic valve replacement with Edwards SAPIEN prosthesis who…
Design
Case_report
Authors
Loading...
Offers bailout option for circulatory collapse in transaortic TAVR; hypothesis-generating and should not yet change practice.
Case Report (n=1)
Demonstrates the feasibility of emergent transaortic placement of an Impella CP device for circulatory collapse during transaortic TAVR when femoral access is unfavorable.
Singh et al. (2014) conducted a case report in Complete circulatory collapse during transaortic TAVR (n=1). Rescue Impella CP placement directly through the ascending aorta was evaluated. Rescue Impella CP placement directly through the ascending aorta was utilized for a patient experiencing complete circulatory collapse during transaortic TAVR with unfavorable femoral access.