Key result
Continuous wrist-derived heart rate moderately correlates with concurrent mYPAS anxiety scores during pediatric surgery induction.
Why the study?
Perioperative anxiety is common in children undergoing surgery, but the validated mYPAS is scored at only discrete timepoints, leaving physiologic status unmeasured between assessments.
Does continuous wrist-derived heart rate monitoring correlate with mYPAS scores and detect between-assessment heart-rate elevations in children undergoing elective surgery?
Observational (n=32)
Does continuous wrist-derived heart rate monitoring correlate with mYPAS scores and detect between-assessment heart-rate elevations in children undergoing elective surgery?
Answers are grounded in this paper and cite their sources.
Continuous wrist-derived heart rate monitoring correlates with intermittent anxiety scores and detects physiologic events between scheduled assessments in children undergoing surgery.
BACKGROUND: Perioperative anxiety affects most children undergoing surgery and predicts emergence delirium, postoperative pain, and behavioral change. The validated modified Yale Preoperative Anxiety Scale (mYPAS) is scored at only a few discrete timepoints, leaving physiologic status between assessments unmeasured. AIMS: We tested whether continuous wearable heart rate correlates with the mYPAS where scored, and whether heart-rate elevations of undetermined cause occur during intervals without concurrent mYPAS observation. METHODS: Children aged 4-17 undergoing elective surgery wore a wrist biosensor (Empatica EmbracePlus) from holding through induction; the mYPAS was scored at consent, parental separation, and induction. We assessed heart rate-mYPAS concordance and the proportion of heart-rate elevations falling outside ±5 min of any mYPAS timepoint, stratified by premedication. RESULTS: Of 32 consented children, 15 were analyzable (median age 10 years, nine male, eight premedicated). Induction-window heart rate correlated with induction anxiety (Spearman ρ = 0.55, 95% CI 0.01-0.84, p = 0.034) and rose into induction in 13 of 15 children (median + 10 beats/min, p = 0.022). Of 90 heart-rate elevations among 14 children with reliable timing, 71% fell outside the assessment windows (95% CI 58%-80%); 12 of 14 (86%) had ≥ 1 event outside all assessment windows. This pattern persisted regardless of premedication. Heart rate tracked children's state self-report (ρ = 0.62, ages ≥ 9) but not trait anxiety; informants agreed modestly. CONCLUSIONS: In this small feasibility cohort, wrist-derived induction-window heart rate was associated with concurrent mYPAS scores. The majority of heart-rate elevations of undetermined cause occurred outside scheduled mYPAS assessment windows. These exploratory findings require confirmation in a larger study incorporating raw physiologic signals, motion measurement, and continuous or event-linked behavioral assessment, which would establish whether continuous physiologic monitoring can complement intermittent behavioral assessment by identifying physiologic events occurring between scheduled anxiety assessments.
No takes yet. Share an insight, caveat, or question.
Safford et al. (2026) conducted an observational in Perioperative anxiety (n=32). Continuous wearable heart rate monitoring (wrist biosensor) was evaluated on Correlation between induction-window heart rate and induction anxiety (mYPAS) (Spearman ρ = 0.55, 95% CI 0.01-0.84, p=0.034). Continuous wrist-derived heart rate during induction correlated with concurrent mYPAS anxiety scores in children undergoing elective surgery.