Key result
Prosthesis-patient mismatch after TAVR is linked to less improvement in delayed H/M ratio and washout rate.
Why the study?
Does prosthesis-patient mismatch after TAVR prevent improvements in cardiac sympathetic nervous function?
Observational (n=44)
No
Does prosthesis-patient mismatch after TAVR prevent improvements in cardiac sympathetic nervous function?
Prosthesis-patient mismatch after TAVR negatively impacts the recovery of cardiac sympathetic nervous function, as measured by delayed H/M ratio and washout rate.
Answers are grounded in this paper and cite their sources.
Prosthesis-patient mismatch may hinder post-TAVR sympathetic recovery; hypothesis-generating and requires prospective confirmation before practice change.
No abstract yet. The journal hasn't published one we can show.
No takes yet. Share an insight, caveat, or question.
Nitta et al. (2020) conducted an observational in Symptomatic severe aortic stenosis (n=44). Prosthesis-patient mismatch (PPM) vs. Absence of prosthesis-patient mismatch was evaluated on Improvement in delayed heart-to-mediastinum (H/M) ratio (ΔDelayed H/M ratio) at 9 months (β = -0.34, p=0.02). Prosthesis-patient mismatch after transcatheter aortic valve replacement was a significant negative predictor of improvements in delayed heart-to-mediastinum ratio and washout rate.
Synapse has enriched 10 related papers. Consider them for comparative context: