Natural convection is still one of mechanisms utilized by advanced pressurized water reactors for its passive containment cooling system. In this case, naturally circulating air cools the outer surface of the containment vessel which is used to remove decay heat released inside the containment. In this study, the simulation using computational fluid dynamics has been carried out to predict the distribution of temperature on the containment model surface, both in the vertical cylinder section and in the ellipsoidal section. The case analyzed is a containment vessel model that is not yet equipped with baffles. The aim will be to provide comparative data in analyzing the use of baffles in increasing natural convection flow in the gap between the containment vessel model and its baffles. The simulation was done for various heat fluxes in the surface of the containment model. It varied from 100 to 500 W/m2 with an increase of (50-100) W/m2 intervals. In addition, based on the analysis results, two correlation equations are also proposed, i.e. the correlation of natural convection heat transfer coefficients for laminar regime on a vertical cylindrical surface and ellipsoidal surface with the heat flux constant in the form of the Nusselt number as a function of the modified Rayleigh number.