Answers are grounded in this paper and cite their sources.
A variety of different possible donor and acceptor impurities have been implanted into GaN and annealed up to 1450 °C. S+ and Te+ produce peak electron concentrations ⩽5×1018 cm−3, well below that achievable with Si+. Mg produces p-type conductivity, but Be+- and C+- implanted samples remained n type. No redistribution was observed for any of the implanted species for 1450 °C annealing. Much more effective damage removal was achieved for 1400 °C annealing of high-dose (5×1015 cm−2) Si+ implanted GaN, compared to the more commonly used 1100 °C annealing.
No takes yet. Share an insight, caveat, or question.
Wilson et al. (1999) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: