Key result
Transaortic PTFE leaflet valve implantation yields improved hemodynamics with no complications in 4 prior Bentall patients.
Why the study?
The study analyzed outcomes of transcatheter aortic valve replacement using a polytetrafluoroethylene leaflet valve in patients with a history of the Bentall-De Bono procedure.
Case Report (n=4)
No
Answers are grounded in this paper and cite their sources.
Transaortic implantation of a polytetrafluoroethylene leaflet valve in patients with a prior Bentall-De Bono procedure is feasible, yielding good hemodynamics and no immediate complications.
Objective: To analyze outcomes of 4 transcatheter aortic valve replacements using a polytetrafluoroethylene leaflet valve in patients with a history of the Bentall–De Bono procedure.Methods: We retrospectively analyzed a series of 4 cases. From February 2019 to March 2022 in Federal Center for Cardiovascular Surgery (Penza, Russia), patients with a history of the Bentall–De Bono procedure underwent transaortic aortic valve implantation of the MedLAB-CT balloon-expandable valve under cardiopulmonary bypass and cardioplegia. Valve No. 25 was implanted in 3 patients, and 1 patient received valve No. 23.Results: According to echocardiography, valve hemodynamic performance improved in the postoperative period: mean and peak pressure gradients were 11.5 and 24 mm Hg, respectively; the median value of effective orifice area was 1.9 cm2, while mitral regurgitation in all cases did not exceed grade 1. Median cardiopulmonary bypass and myocardial ischemia times were 59 and 31 minutes, respectively. There was no immediate and remote mortality. No complications were reported in the postoperative period.Conclusion: The proposed replacement of the valved conduit’s compromised part after the Bentall–De Bono procedure can significantly reduce the extent of surgery, cardiopulmonary bypass and myocardial ischemia times, as well as simplify the procedure. Received 1 December 2022. Revised 10 February 2023. Accepted 16 February 2023. Informed consent: The patient’s informed consent to use the records for medical purposes is obtained. Funding: The study did not have sponsorship. Conflict of interests: The authors declare no conflict of interest. Contribution of the authorsLiterature review: V.A. Karnakhin, I.D. PotopalskiyDrafting the article: V.V. Bazylev, A.B. Voevodin, I.D. Potopalskiy, V.A. KarnakhinCritical revision of the article: A.A. Kuznetsova, M.P. PatelSurgical treatment: V.V. Bazylev, A.B. VoevodinFinal approval of the version to be published: V.V. Bazylev, A.B. Voevodin, I.D. Potopalskiy, V.A. Karnakhin, M.P. Patel, A.A. Kuznetsova
No takes yet. Share an insight, caveat, or question.
Базылев et al. (2023) conducted a case report in History of the Bentall-De Bono procedure (n=4). Transaortic aortic valve implantation of the MedLAB-CT balloon-expandable valve was evaluated on Valve hemodynamic performance, mortality, and postoperative complications. Transaortic implantation of a polytetrafluoroethylene leaflet valve in 4 patients with prior Bentall-De Bono procedure yielded improved hemodynamics with 0% mortality and no complications.
Synapse has enriched 10 related papers. Consider them for comparative context: