Key result
St. Jude mechanical tricuspid valve replacement shows ~87% 10-year survival with low thrombosis rates.
Why the study?
Mechanical valves remain valuable for tricuspid valve replacement, especially for patients wishing to avoid reoperation for bioprosthetic valve malfunction.
What are the long-term clinical outcomes and complication rates of tricuspid valve replacement using the St. Jude Medical mechanical valve?
Observational (n=265)
No
What are the long-term clinical outcomes and complication rates of tricuspid valve replacement using the St. Jude Medical mechanical valve?
The St. Jude Medical mechanical valve is a reliable option for tricuspid valve replacement, demonstrating high long-term survival and low rates of valve thrombosis and reoperation.
Answers are grounded in this paper and cite their sources.
High survival with low thrombosis may support mechanical tricuspid replacement in select patients; leaves open randomized comparisons to bioprostheses.
Bioprosthetic valves for tricuspid valve replacement (TVR) have become increasingly popular in recent years, but mechanical valves remain valuable, particularly for the patients who want to avoid reoperation for bioprostheses malfunction. The aim of this study was to review our 10-year experience in adult patients who underwent TVR with the St. Jude Medical (SJM) valve. From 2005 to 2015, 265 TVRs with SJM valves were performed at our institution. The mean age at operation was 44.1 ± 9.7 years, and 207 cases (78.1%) were female. The mean follow-up was 4.9 ± 2.7 years. Preoperative atrial fibrillation was present in 199 cases (75.1%) and ascites in 26 (9.8%). Of all cases, 88.7% were characterized as New York Heart Association class III or IV. The hospital mortality was 6.4%. There were 9 deaths (3.8%) during late follow-up. The overall survival rates were 89.2% ± 2.2% at 5 years and 86.6% ± 2.9% at 10 years. The linearized rates of valve thrombosis and bleeding events were 0.8%/patient-year and 1.5%/patient-year, respectively. Three cases (1.3%) were reoperated due to prosthetic valve thrombosis. There was no reoperation for sperivalvular leakage and structural failure. The freedom from reoperation was 98.6% ± 0.8% at 5 years and 98.6% ± 0.8% at 10 years. The SJM valve in the tricuspid position is a reliable mechanical prosthesis with a low rate of valve thrombosis and reoperation. It is a reasonable choice for the patients who require mechanical valve replacement in the tricuspid position.
No takes yet. Share an insight, caveat, or question.
Zhu et al. (2018) conducted an observational in Tricuspid valve disease requiring replacement (n=265). Tricuspid valve replacement with St. Jude Medical valve was evaluated on 10-year overall survival. Tricuspid valve replacement with the St. Jude Medical mechanical valve demonstrated an overall survival rate of 86.6% at 10 years, with a low linearized rate of valve thrombosis of 0.8% per patient-year.