Key result
Dynamic Savitzky-Golay filtering successfully separates trunk muscle EMG from ECG signals without distortion.
Why the study?
Does the dynamic application of a Savitzky-Golay filter improve the separation of ECG artifacts from EMG signals compared to a Butterworth filter?
Does the dynamic application of a Savitzky-Golay filter improve the separation of ECG artifacts from EMG signals compared to a Butterworth filter?
A novel dynamic Savitzky-Golay filter effectively removes ECG artifacts from EMG signals without distorting the underlying EMG data, offering an improvement over traditional high-pass filters.
May enhance trunk EMG quality during ECG-contaminated recordings; leaves open prospective validation versus Butterworth filters.
Trunk muscle electromyographic (EMG) signals are often contaminated by the electrical activity of the heart. During low or moderate muscle force, these electrocardiographic (ECG) signals disturb the estimation of muscle activity. Butterworth high-pass filters with cut-off frequency of up to 60 Hz are often used to suppress the ECG signal. Such filters disturb the EMG signal in both frequency and time domain. A new method based on the dynamic application of Savitzky-Golay filter is proposed. EMG signals of three left trunk muscles and pure ECG signal were recorded during different motor tasks. The efficiency of the method was tested and verified both with the experimental EMG signals and with modeled signals obtained by summing the pure ECG signal with EMG signals at different levels of signal-to-noise ratio. The results were compared with those obtained by application of high-pass, 4th order Butterworth filter with cut-off frequency of 30 Hz. The suggested method is separating the EMG signal from the ECG signal without EMG signal distortion across its entire frequency range regardless of amplitudes. Butterworth filter suppresses the signals in the 0-30 Hz range thus preventing the low-frequency analysis of the EMG signal. An additional disadvantage is that it passes high-frequency ECG signal components which is apparent at equal and higher amplitudes of the ECG signal as compared to the EMG signal. The new method was also successfully verified with abnormal ECG signals.
No takes yet. Share an insight, caveat, or question.
Christov et al. (2018) studied this question. Dynamic application of Savitzky-Golay filter vs. High-pass, 4th order Butterworth filter with cut-off frequency of 30 Hz was evaluated on Separation of EMG signal from ECG signal without distortion. A new method based on the dynamic application of a Savitzky-Golay filter successfully separated trunk muscle EMG signals from ECG signals without distortion across the entire frequency range.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: