Key result
Cadaveric aortic evaluation reveals high anatomical variability including a ~21% decrease in descending aorta diameter.
Why the study?
Current stent design does not account for complex advanced CVD in the aortic arch and abdominal aorta within high-risk populations.
Significant anatomical variations in the aorta, including high taper and tortuosity, highlight the need for refined stent-graft designs for populations with advanced cardiovascular disease.
Answers are grounded in this paper and cite their sources.
Anatomical variability may require tailored vascular interventions; leaves open confirmation of prevalence and impact in living patients.
The prevalence and complexity of cardiovascular disease (CVD) in the West of Scotland are high with the aortic arch and abdominal aorta, particularly at increased risk of cardiovascular pathology. Stent deployment can be key in preventing further cardiovascular events, however, current stent design does not account for complex advanced CVD in these areas. This cadaveric study aimed to provide anatomical measurements requested by manufacturers to improve stent design and deployment in this target population. Nine cadavers (six females and three males; age range = 82.7 ± 10.4 years) from the West of Scotland were dissected to expose the aortic arch and abdominal aorta. Digital callipers and protractors were used to collect data on vessel diameters (including taper), branch spacing, angles and presence of collaterals. CVD was present in all cadavers and ranged from mild plaque presence to aortic dissections. One possessed a bovine aortic arch variation. Supra-aortic vessels were approximately equally spaced, but the left common carotid had the most acute branching angle. Angulation of the arch from the coronal plane positively correlated with a deviation of the left subclavian artery (LSA) from the sternal midline (Spearman's coefficient r = 0.82, p = 0.01) which may impact surgical access. The origin of the vertebral artery on the LSA was also highly variable. The diameter of the descending aorta decreased along its length from the aortic hiatus to superior mesenteric by 21 ± 10% indicating a high degree of taper. The artery of Adamkiewicz was present in 33% and additional renal collaterals were present in 22%. 66% had tortuous vessels in the abdominal region. These results highlight the need for more data to aid the refinement of stent-graft design and deployment methods to ensure successful surgical intervention in this population.
No takes yet. Share an insight, caveat, or question.
Allardyce et al. (2022) studied Cardiovascular disease (n=9). Anatomical variation of the aorta was evaluated on Anatomical measurements including vessel diameters, branch spacing, angles, and presence of collaterals. Anatomical evaluation of 9 cadavers revealed high variability, including a 21% decrease in descending aorta diameter and tortuous abdominal vessels in 66%.
Synapse has enriched 10 related papers. Consider them for comparative context: