Key result
Modified mitral valve repair using autologous pericardium and artificial chordae successfully replaces infected tissue in IE.
Why the study?
Does mitral valve repair using autologous pericardium and artificial chordae improve prospects in patients with advanced active infective endocarditis?
Case Report
Does mitral valve repair using autologous pericardium and artificial chordae improve prospects in patients with advanced active infective endocarditis?
This technical modification demonstrates the feasibility of using autologous pericardium and artificial chordae for complex mitral valve repair in active infective endocarditis.
Answers are grounded in this paper and cite their sources.
May enable mitral repair in extensive anterior leaflet destruction; hypothesis-generating and requires validation before wider adoption.
In patients with active infective endocarditis mitral valve repair is better than mitral valve replacement, but it remains a challenge when there has been massive destruction of the rough zone of the anterior leaflet. We report a technical modification of mitral valve repair for advanced active infective endocarditis in which a widely infected rough zone and the chordae were successfully replaced with autologous pericardium and multiple artificial chordae. The procedure described here is capable of improving the prospects of mitral valve repair in advanced infective endocarditis.
No takes yet. Share an insight, caveat, or question.
Shin et al. (2010) conducted a case report in Active infective endocarditis. Mitral valve repair with autologous pericardium and multiple artificial chordae was evaluated. A technical modification of mitral valve repair using autologous pericardium and artificial chordae successfully replaced a widely infected rough zone in advanced active infective endocarditis.
Synapse has enriched 10 related papers. Consider them for comparative context: