Key result
LBB entrainment mapping shows concealed fusion with ~3 ms PPI-TCL, suggesting upper turnaround near the LBB.
Why the study?
The anatomic extent of the reentry circuit in idiopathic left posterior fascicular ventricular tachycardia is not fully elucidated, particularly the upper turnaround point.
Does entrainment mapping at the LBB and HB regions delineate the upper turnaround point of the reentry circuit in patients with LPF-VT?
Observational (n=23)
Does entrainment mapping at the LBB and HB regions delineate the upper turnaround point of the reentry circuit in patients with LPF-VT?
Answers are grounded in this paper and cite their sources.
Entrainment mapping demonstrates that the upper turnaround point of the LPF-VT reentry circuit extends to the proximal His-Purkinje system near the LBB region.
BACKGROUND: The anatomic extent of the reentry circuit in idiopathic left posterior fascicular ventricular tachycardia (LPF-VT) is yet to be fully elucidated. We hypothesized that entrainment mapping could be used to delineate the reentry circuit of an LPF-VT, especially including the upper turnaround point. METHODS: Twenty-three consecutive LPF-VT patients (mean age, 29 ± 9 years, 18 males) were included. We performed overdrive pacing with entrainment attempts at the left bundle branch (LBB) and the left His bundle (HB) region. RESULTS: Overdrive pacing from the LBB region showed concealed fusion in all 23 patients (post-pacing interval [PPI], 322.1 ± 64.3 ms; tachycardia cycle length [TCL], 319.0 ± 61.6 ms; PPI-TCL, 3.1 ± 4.6 ms) with a long stimulus-to-QRS interval (287.9 ± 58.0 ms, approximately 90% of the TCL). Pacing from the same LBB region at a slightly faster pacing rate showed manifest fusion with antidromic conduction to the LBB and minimal in-and-out time to the LBB potential (PPI-TCL, 21.3 ± 13.7 ms). Overdrive pacing from the left HB region showed manifest fusion with a long PPI-TCL (53.9 ± 22.5 ms). CONCLUSIONS: Our pacing study results suggest that the upper turnaround point in a reentry circuit of the LPF-VT may extend to the proximal His-Purkinje conduction system near the LBB region but below the left HB region. The LPF may constitute the retrograde limb of the reentry circuit.
No takes yet. Share an insight, caveat, or question.
Hwang et al. (2023) conducted an observational in Idiopathic left posterior fascicular ventricular tachycardia (LPF-VT) (n=23). Entrainment mapping with overdrive pacing was evaluated on Post-pacing interval minus tachycardia cycle length (PPI-TCL) at the left bundle branch region. Entrainment mapping with overdrive pacing at the left bundle branch region showed concealed fusion with a short PPI-TCL, suggesting the upper turnaround point extends near the LBB.
Synapse has enriched 10 related papers. Consider them for comparative context: