Key result
CRT-D upgrade with anterior cardiac vein LV lead improves pacing and suppresses arrhythmias after right pneumonectomy.
Case Report (n=1)
Amiodarone can cause high initial pacing thresholds during CRT-D upgrade, which may improve significantly after the drug is discontinued, allowing for non-conventional lead placement when anatomy is limiting.
Answers are grounded in this paper and cite their sources.
Supports anterior cardiac vein LV lead placement post-pneumonectomy; leaves open generalizability beyond this single case.
A 73-year-old male with a history of right pneumonectomy had a single-chamber defibrillator implanted for secondary prevention. He required a cardiac resynchronization therapy defribillator upgrade as he had worsening symptoms with VVI pacing. He was admitted for ventricular tachycardia storm and was started on intravenous amiodarone prior to upgrade. The coronary sinus venogram (see Supplementary video) showed an ideal lateral target vein but there was either no capture at 7.5 V or phrenic stimulation in all possible positions in that vein. With no other options we made the decision to position the left ventricular (LV) lead in the anterior cardiac vein with a threshold of 4.5 V at 1.5 ms (see figure). His right atrial (RA) lead also had a high threshold of 2 V at 1.5 ms. Following this procedure, his amiodarone was weaned off and his pacing threshold improved significantly and had no episodes of ventricular arrhythmia at 9 months of follow-up. In this patient, we had to place the LV lead in a non-conventional position due to limitation of his venous anatomy. Epicardial lead was also not in consideration in view of his previous pneumonectomy and anaesthesia risk. Pacing threshold <2 V has been accepted as optimal but in our patient, we had to accept the high initial pacing threshold as a result of amiodarone usage during implant. When we rechecked our patient 2 weeks after stopping amiodarone, his RA pacing threshold was 0.5 V at 1.5 m and his LV pacing threshold dropped to 1.75 V at 1.5 ms. Supplementary material is available at Europace online. The full-length version of this report can be viewed at: http://www.escardio.org/communities/EHRA/publications/ep-case-reports/Documents/crt-upgrade-pneumonectomy.pdf
No takes yet. Share an insight, caveat, or question.
Chow et al. (2012) conducted a case report in Ventricular tachycardia storm and worsening symptoms with VVI pacing (n=1). CRT-D upgrade with LV lead placement in the anterior cardiac vein was evaluated on Pacing threshold and ventricular arrhythmia episodes. In a patient with a previous right pneumonectomy, CRT-D upgrade with LV lead placement in the anterior cardiac vein resulted in improved pacing thresholds and no ventricular arrhythmias at 9 months.
Synapse has enriched 10 related papers. Consider them for comparative context: