Key result
Esophageal cooling reduces endoscopic lesions ~83% vs standard temperature monitoring during LA ablation.
Why the study?
Collateral thermal injury to the esophagus remains a concern during left atrial ablation for atrial fibrillation.
Does cooling or warming the esophagus using a temperature management device reduce esophageal injury in patients undergoing left atrial ablation for atrial fibrillation?
Does cooling or warming the esophagus using a temperature management device reduce esophageal injury in patients undergoing left atrial ablation for atrial fibrillation?
This protocol describes a method for using an esophageal temperature management device to mitigate thermal injury during left atrial ablation for atrial fibrillation.
Answers are grounded in this paper and cite their sources.
Supports investigation of dedicated esophageal cooling in left atrial ablation; should not yet change practice pending randomized trials.
Ablation of the left atrium using either radiofrequency (RF) or cryothermal energy is an effective treatment for atrial fibrillation (AF) and is the most frequent type of cardiac ablation procedure performed. Although generally safe, collateral injury to surrounding structures, particularly the esophagus, remains a concern. Cooling or warming the esophagus to counteract the heat from RF ablation, or the cold from cryoablation, is a method that is used to reduce thermal esophageal injury, and there are increasing data to support this approach. This protocol describes the use of a commercially available esophageal temperature management device to cool or warm the esophagus to reduce esophageal injury during left atrial ablation. The temperature management device is powered by standard water-blanket heat exchangers, and is shaped like a standard orogastric tube placed for gastric suctioning and decompression. Water circulates through the device in a closed-loop circuit, transferring heat across the silicone walls of the device, through the esophageal wall. Placement of the device is analogous to the placement of a typical orogastric tube, and temperature is adjusted via the external heat-exchanger console.
No takes yet. Share an insight, caveat, or question.
Zagrodzky et al. (2020) studied Atrial Fibrillation. Esophageal temperature management device was evaluated. Esophageal cooling using a dedicated temperature management device has been shown to reduce endoscopically identified lesions by 83% compared to standard luminal esophageal temperature monitoring during left atrial ablation.