Key result
Bioabsorbable occluders for perimembranous VSDs achieve 100% technical success without new regurgitation or AV block.
Why the study?
Conventional metallic occluders for pmVSDs carry risks of long-term complications, and the application of fully bioabsorbable occluders in children with moderate-to-large pmVSDs remains under-reported.
Is TEE-guided transthoracic implantation of a bioabsorbable occluder safe and feasible in children with moderate-to-large perimembranous ventricular septal defects?
Observational (n=5)
No
Is TEE-guided transthoracic implantation of a bioabsorbable occluder safe and feasible in children with moderate-to-large perimembranous ventricular septal defects?
TEE-guided transthoracic closure of moderate-to-large perimembranous ventricular septal defects using bioabsorbable occluders is feasible and safe in children, showing favorable 1-year valvular and conduction outcomes with progressive device degradation.
Hypothesis-generating for bioabsorbable occluders in pediatric pmVSD; prospective trials needed before clinical adoption.
Objectives: Transcatheter closure has become an important treatment modality for perimembranous ventricular septal defects (pmVSDs). However, conventional metallic occluders carry the risk of long-term complications. Fully bioabsorbable occluders offer a potential solution, yet their application in children with moderate-to-large pmVSDs remains under-reported. This study evaluated the feasibility and 1-year outcomes of transthoracic, transesophageal echocardiography (TEE)-guided implantation of a bioabsorbable occluder via a small subxiphoid incision in children with moderate-to-large pmVSDs. Methods: Children aged ≥1 year with moderate-to-large pmVSDs (defined as left ventricular defect diameter exceeding one-third of the aortic root diameter) who underwent TEE-guided transthoracic device closure using a bioabsorbable occluder between July 2024 and January 2025 were prospectively enrolled. Baseline characteristics, procedural data, and follow-up outcomes at 1, 3, 6, and 12 months were collected. The primary endpoints were technical success, valvular function, conduction disturbance, and occluder degradation. Results: Five children (mean age 2.4 ± 1.7 years; mean weight 12.6 ± 4.6 kg; mean defect diameter 8.8 ± 2.6 mm) were included. All implants were successful (technical success 100%). One patient with a multi-fenestrated defect had a 2 mm residual shunt immediately post-procedure, which resolved by 6 months. At 1 year, no patient developed new-onset or worsening aortic regurgitation (AR) or tricuspid regurgitation (TR), and none had complete atrioventricular block (cAVB). Quantitative echocardiographic analysis showed that occluder disc area decreased substantially at 1 year, indicating progressive absorption. Conclusions: TEE-guided transthoracic closure of moderate-to-large pmVSDs using a bioabsorbable occluder appears feasible in selected children. One-year follow-up data suggest favorable preservation of valvular and conduction function, with progressive occluder degradation. This approach may offer a minimally invasive alternative to surgery for this challenging population, although larger studies are warranted.
No takes yet. Share an insight, caveat, or question.
Chen et al. (2026) conducted an observational in Moderate-to-large perimembranous ventricular septal defects (n=5). Transcatheter closure using a bioabsorbable occluder was evaluated on Technical success.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: