Key result
24-hour intraarterial BP correlates more strongly with target organ damage than casual cuff BP.
Why the study?
Does 24-h intraarterial blood pressure monitoring correlate better with target organ damage than cuff sphygmomanometer measurements in hypertensive patients?
Observational (n=108)
Does 24-h intraarterial blood pressure monitoring correlate better with target organ damage than cuff sphygmomanometer measurements in hypertensive patients?
24-hour blood pressure means and variability are superior to casual cuff measurements in correlating with target organ damage in hypertensive patients.
Answers are grounded in this paper and cite their sources.
Supports 24-h intraarterial BP monitoring over cuff readings for target organ damage assessment; hypothesis-generating and should not yet change practice.
Casual blood pressure measurements can predict the development of cardiovascular morbidity and mortality, but especially in mild hypertension the correlation indices between casual measurements of blood pressure and the subsequent occurrence of complications are low. Casual and office blood pressure measurements, however, provide a very limited and biased assessment of blood pressure as a risk factor since blood pressure is known to change from moment to moment and to be influenced by its very measurement. Considerable advances in our understanding of the factors influencing blood pressure during daily life and in assessing blood pressure variability have been made possible by use of portable equipment for continuous intraarterial recording of blood pressure. Equipment for noninvasive ambulatory blood pressure monitoring is also available; this equipment is more practical than intraarterial equipment, but is associated with some degree of error and several limitations. Data are reported from a recent study conducted by our group in which target organ damage in 108 hypertensive patients was correlated with blood pressure values as measured by a cuff sphygmomanometer and with various indices derived from 24-h intraarterial blood pressure monitoring. The findings indicate that the incidence and severity of organ damage are more closely related to 24-h blood pressure means than to cuff values. They also provide the first unequivocal evidence that target organ damage also relates to blood pressure variability.
No takes yet. Share an insight, caveat, or question.
Zanchetti et al. (1987) conducted an observational in Hypertension (n=108). 24-h intraarterial blood pressure monitoring vs. Cuff sphygmomanometer was evaluated on Incidence and severity of target organ damage. 24-hour intraarterial blood pressure means and variability were more closely related to the incidence and severity of target organ damage than casual cuff blood pressure values.
Synapse has enriched 10 related papers. Consider them for comparative context: